Alarms
Alarms
The following table describes the detector alarms and corresponding screens.
• During an alarm condition, the detector activates the backlight and displays the current ambient gas reading.
• If more than one type or level of alarm exists simultaneously, a multi alarm results.
• To change the factory-set alarm setpoints, refer to
Calibration and Setting Alarm Setpoints
.
Table 7. Alarms
Alarms
Screen`
Alarms
Screen
Low Alarm
•
Fast beep
•
Slow flash
•
L
and gas type flash
•
Vibrator alarm activates
TWA Alarm
•
Fast beep
•
Slow flash
•
L
and gas type flash
•
Vibrator alarm activates
High Alarm
•
Constant beep
•
Fast flash
•
L
and gas type flash
•
Vibrator alarm activates
STEL Alarm
•
Constant beep
•
Fast flash
•
L
and gas type flash
•
Vibrator alarm activates