CDMA-X Installation and Setup Guide
– 19 –
[S]
ECP Flt
OK
Program Mode
Displays either ECP mode or the zones if 4204 / two-4204 was chosen.
Flt
Displays the communicator fault status.
OK = Normal, No fault.
G = No network connectivity over CDMA and fault time has expired.
g = No network connectivity over CDMA and fault time has NOT yet expired.
[T]
Test Msg Sent
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a
registered
communicator only. If
the device is not registered, a message is displayed indicating that the command
cannot be executed.
[X]
Reset CPU Y/N
Reset the communicator.
Pressing [N] returns to normal mode.
Pressing [Y] resets the device.
Note, this resets the CPU and does not affect the programming.
[Shift]
[
↑
]
(UP arrow)
Registering …
Registration
Registers a programmed communicator with AlarmNet.
[
↓
]
(DN arrow)
Enter PIN#
Registration with PIN for Replacement Module
Registers a replacement communicator with AlarmNet, once programmed, using the
existing PIN #.
[0]
Force Server
Update?
Y/N
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configuration file to the server.
Pressing [N] cancels the operation.
NOTE:
If the communicator is not initialized when you enter this command, the
following screen will be displayed:
Cannot Upload
Try Later! _
Wait for the SIGNAL (green) LED to light, indicating the communicator has
completed its initialization, and try again.
[ENTER]
Strt Prog Mode?
Y/N_
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].
Central Station Messages
The following messages are sent to the Central Station by AlarmNet for the conditions listed below.
NOTE:
The control
panel sends its own general code (E353) for a trouble condition.
ECP Mode
4204 Modes
Alarm Condition
Alarm Code
Restore Code
Alarm Code
Restore Code
Power On / Reset (xx=device address) E339 C08xx
5551 5555 6
ECP Supervision
E355 C0000
R355 C0000
5555 5515 5
5555 5535 5
Communication Path Supervision
R350 C0951
5555 5553 5
Code Download Begin
E903 C0803
Code Download End Successful
n/a
R903 C0803
Code Download Failed
E904 C0803
Test
5555 5555 9
5555 5555 9