CDMA-X Installation and Setup Guide
– 14 –
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
46
Delay Zn8 (secs)
(00)
only
2-4204
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 8.
47
Review? Y/N
[Y] = review
[N] = exit
Reviewing Programming Mode Entries
To review the programming options (to ensure that the
correct entries have been made), press [Y]. The
programming prompts are displayed again. Use the
up/down arrow keys to scroll through the program
fields without changing any of the values. If a value
requires change, simply type in the correct value.
When the last field is displayed, the “REVIEW?”
prompt again appears.
To exit the programming mode
, press [N] in
response to the "REVIEW?" prompt, and refer to
Exiting Programming Mode
topic.
ECP Status Codes
The communicator sends status messages to the control panel to report various failures. Some control panels, (e.g.,
VISTA-10P, VISTA-15P and VISTA-20P Series) display these status codes on the keypad as “LngRng Radio” followed by a
4-digit code. Commercial panels can supervise the communicator by way of its ECP address, ex: 03. For example, if the
communicator is disconnected, if it's not registered, or the communicator is deactivated, a "Check 803" will be displayed.
The control panel will display a fault message if any of the events listed below occur.
•
Module lost communications with the control panel.
•
Module lost contact with AlarmNet.
•
Module is not registered; account not activated.
•
Module shutdown.
In addition, the Contact ID codes for some of these conditions are reported by the control panel and sent by AlarmNet to
the central station.
Exiting the Programming Mode
To exit the programming mode, press [N] in response to the "REVIEW?" question. Then press [Y] to the "Exit Prog Mode?"
question. Upon exiting, the message “Checking Root File TX Path” will be displayed, and the configuration file at the
server is updated to log the changes made. When complete, the message "DONE" is displayed to indicate the file was
successfully uploaded.
If critical configuration changes were made, such as the mode of operation, the communicator will reset to ensure that the
programming features are enabled.
If the file is not successfully uploaded, one of the following prompts will be displayed. Follow the steps shown below until
the upload is successful.
Display
Description
What to do
Cannot Upload
Try Again? Y/N_
Communicator has not yet
initialized.
Wait for SIGNAL (green) LED to be lit.
Press [Y].
Failed to Update
Root File!
Network problem, or you answered
"N" to "Cannot Upload Try Again?"
prompt.
Initiate the Force Server Update command by
pressing the [0] key.