CDMA-X Installation and Setup Guide
– 12 –
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
22
Telco Zone
(0)_
only
4204
2-4204
4204: [1-4]
2-4204:
[1-8]
[0] = not used
See "Important Information Regarding Zone Input
Options" on previous page.
Enter the zone number to be used for Telco line fault
reports. This zone assignment must be unique from
the open/close zone selected in Prompt 23.
4204 Mode:
If any zone is programmed for "report
only if armed," zone 4 cannot be used as a Telco
zone.
2-4204 Mode:
If any zone is programmed for "report
only if armed," zone 8 cannot be used.
NOTE:
Connect the Telco line fault output (or relay
output programmed for "Telco line fault") to the Telco
zone.
23
Open/
Close Zone (0)
only
4204
2-4204
4204: [1-4]
2-4204:
[1-8]
[0] = not used
Enter the zone number to be used for open/close
(arm/disarm) reports. This zone assignment must be
unique from the Telco zone selected in Prompt 22.
4204 Mode:
If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode:
If any zone is programmed for "report
only if armed," zone 8 cannot be used.
NOTE:
Connect an open/close (arm/disarm) trigger (or
relay output) from the control panel to the open/close
zone.
24
Restore Zn1 Y/N
(Y)
only
4204
2-4204
[Y], [N]
Enables restore reporting for
zone 1.
25
Delay Zn1 (secs)
(00)
only
4204
2-4204
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 1.
26
Rpt Zn1 ONLY if
Armed
(N)
only
4204
2-4204
[Y], [N]
Reports alarms on zone 1 ONLY if the conditional zone
(zone 4 in 4204 mode; or zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 1.
27
Restore Zn2 Y/N
(Y)
only
4204
2-4204
[Y], [N]
Enables restore reporting for
zone 2.
28
Delay Zn2 (secs)
(00)
only
4204
2-4204
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 2.
29
Rpt Zn2 ONLY if
Armed
(N)
only
4204
2-4204
[Y], [N]
Reports alarms on zone 2 ONLY if the conditional zone
(zone 4 in 4204 mode; or zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
30
Restore Zn3 Y/N
(Y)
only
4204
2-4204
[Y], [N]
Enables restore reporting for
zone 3.
31
Delay Zn3 (secs)
(00)
only
4204
2-4204
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 3.