Page A-11
28 Feb 2018
23-15-45
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
Aspire-200
© Honeywell International Inc. Do not copy without express permission of Honeywell.
10. CCU-200
Section
Environmental Condition
DO-160E
Category
4
Temperature and Altitude
A2
4
In Flight Loss of Cooling
A2V
5
Temperature Variation
B
6
Humidity
B
7
Operational Shocks and ash Safety
B
8
Vibration (operational)
S B2
9
Explosive Atmosphere
E
10
Waterproofness
W
11
Fluids Susceptibility
F
12
Sand and Dust
X—not required
13
Fungus Resistance
X—not required
14
Salt Fog
X—not required
15
Magnetic Effect
X—not required
16
Power Input
A
16
Normal Surge Voltage
Z
16
Abnormal Surge Voltage
Z
17
Voltage Spike
A
18
Audio Frequency Conducted Susceptibility–Power Input
Z
19
Induced Signal Susceptibility
AC
20
Radio Frequency Susceptibility
A
21
Emission of Radio Frequency Energy
M
22
Lightning Induced Transient Susceptibility
X—not required
23
Lightning Direct Effects
X—not required
24
Icing
X—not required
25
Electrostatic Discharge (ESD)
A
26
Fire, Flammability
X—not required