![Honeywell Ademco VISTA-50P Installation And Setup Manual Download Page 62](http://html.mh-extra.com/html/honeywell/ademco-vista-50p/ademco-vista-50p_installation-and-setup-manual_153286062.webp)
VISTA-50P/VISTA-50PUL Installation and Setup Guide
5-14
FIELD
TITLE and DATA ENTRIES
EXPLANATION
2*02
Daylight Saving Time Start/End
Weekend
0
= disable
1
= enable
Enter the start and end weekends for daylight saving time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from
last. Standard setting for U.S. is 1,5.
UL
Fields 2*05 – 2*08 must be set to 0 for UL installations.
2*05
Auto-Arm Delay (partition-
specific)
00
= no delay.
01-14
times 4 minutes (04-56) delay.
15
= no auto arming.
This is the time between the end of the arming window and the start of
auto-arm warning time (field 2*06).
2*06
Auto-Arm Warning Period
(partition-specific)
01-15
times 1-minute warning.
00
= no warning period.
This is the time that the user is warned by a keypad sounding and display
to exit the premises prior to auto arming of the system.
2*07
Auto-Disarm Delay (partition-
specific)
00
= no delay.
01-14
times 4 minutes (04-56) delay.
15
= no auto disarming.
This is the time between the end of the disarming window and the start of
auto disarming of the system.
2*08
Force Arm Enable for Auto-Arm
(partition-specific)
0
= disable
1
= enable
If enabled, the system automatically bypasses any faulted zones when it
attempts to auto-arm.
If disabled, the system will not auto-arm.
2*09
Open/Close Reports by
Exception (partition-specific)
0
= disable
1
= enable
If enabled, Open/Close reports are sent
only if
the openings/closings
occur
outside
the arm and disarm windows.
NOTES:
Open reports are also suppressed during the closing window in order to
prevent false alarms if the user arms the system, then re-enters the
premises, for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
This field
must
be set to
1
if No Opening and No Closing reports are to be
sent.
2*10
Allow Disarming Only During
Arm/Disarm Windows (partition-
specific)
0
= disable
1
= enable
If enabled, disarming of the system is allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to
1).
NOTE:
This applies
only
to Operator-level users. Installer, Master, and
Manager-level users can disarm the system at any time.
2*11
Allow Disarm Outside Window if
Alarm Occurs
0
= disable
1
= enable
If enabled, allows the system to be disarmed outside the programmed
disarm (opening) window if an alarm has occurred. Otherwise disarming
is allowed only during the disarm window.
NOTE:
Used only if field 2*10 is enabled.
2*13
Scheduling Report Codes (First
Digit
Enter
00-15
.
This field has eight two-digit entries as follows: Early Opening, Early
Closing, Late Opening, Late Closing, No Opening (late to open), No
Closing (late to close), Auto-Arm Failure, and Access Schedule Changed.
Enter the report code
01-15
for each type of report. Enter
00
for no report.
WWW.DIYALARMFORUM.COM
Summary of Contents for Ademco VISTA-50P
Page 2: ...ii WWW DIYALARMFORUM COM ...
Page 12: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 2 4 WWW DIYALARMFORUM COM ...
Page 40: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 3 28 WWW DIYALARMFORUM COM ...
Page 48: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 4 8 WWW DIYALARMFORUM COM ...
Page 64: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 5 16 WWW DIYALARMFORUM COM ...
Page 78: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 6 14 WWW DIYALARMFORUM COM ...
Page 82: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 7 4 WWW DIYALARMFORUM COM ...
Page 84: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 8 2 WWW DIYALARMFORUM COM ...
Page 98: ...VISTA 50P VISTA 50PUL Installation and Setup Guide B 2 WWW DIYALARMFORUM COM ...
Page 100: ...VISTA 50P VISTA 50PUL Installation and Setup Guide C 2 WWW DIYALARMFORUM COM ...
Page 102: ...VISTA 50P VISTA 50PUL Installation and Setup Guide D 2 WWW DIYALARMFORUM COM ...
Page 110: ...WWW DIYALARMFORUM COM ...
Page 111: ...WWW DIYALARMFORUM COM ...