1*41
Non-Alarm Report Codes Report
Codes (Second Digit)
Enter
00-15
.
This field has seven two-digit entries as follows: Arm STAY, Time/Date
set or Event Log Reset, Event Log 50% or 90% Full, Event Log Overflow,
Exit Error (Zone), Exit Error (User) and Recent Close. Enter the report
code
01-15
for each type of report. Enter
00
for no report.
1*42
Call Waiting Defeat
0
= disable
1
= enable
If enabled, the system defeats Call Waiting on the first outgoing call
attempt to both the primary and secondary numbers.
NOTES:
After the panel’s initial call to report the alarm, the panel may attempt to
make an additional call, perhaps for a cancel or a zone restoral. If Call
Waiting is not defeated, an operator at the central station attempting to
contact the premises (to verify whether the alarm is valid) hears the
phone ringing indefinitely and must to dispatch on the call.
DO NOT enable this feature unless Call Waiting is being used.
1*43
Permanent Keypad Display
Backlighting (partition-specific)
0
= disable
1
= enable
If enabled, backlighting for the keypad display remains on at all times.
Otherwise the backlighting comes on when a key is pressed.
NOTE:
When a key is pressed, display backlighting turns on for
all
keypads in that partition.
1*44
Wireless Keypad Tamper Detect
0
= disable
1
= enable
If enabled, when more than 40 key depressions are received without a
valid sequence (arm, disarm, etc.), the control panel disables the wireless
keypad. The inhibit is removed once a valid key sequence is received from
a wired keypad.
1*45
Exit Delay Sounding (partition-
specific)
0
= disable
1
= enable
If enabled, the system produces slow beeping from the keypads during
exit delay and reverts to rapid beeping during the last 10 seconds of the
exit delay.
NOTE:
The duration of the beeping is the programmed value of field *10
regardless of which entry/exit zone is used to exit the premises.
1*46
Auxiliary Output Mode
0
= ground start output.
1
= open/close trigger.
2
= keypad sounds at an auxiliary sounder.
3
= AAV module.
Select the mode for output 1 on the J7 triggers.
NOTES:
Only one of the options may be active within the system.
Selection 1 is produced only when all partitions are armed.
Selection 2 applies only to the partition enabled in field *15.
1*47
Chime on External Siren
(partition-specific)
0
= disable
1
= enable
If enabled, the system produces chime annunciation on the external
alarm sounder.
1*48
Wireless Keypad Assignment
0
= none
1-8
= partition number
Select the partition in which RF keypad is used.
1*49
Suppress Transmitter
Supervision Sound
0
= disable
1
= enable
If enabled, no trouble soundings occur on the keypad for transmitter
check-in failures.
Must be
0
for UL.
1*52
Send Cancel If Alarm + Off
(partition-specific)
0
= disable
1
= enable
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTE:
This option must be enabled so Cancel reports are always sent.
1*53
Disable Download Callback
0
= callback required
1
= no callback required
Select whether a callback from the control panel is required for
downloading.
Must be
0
for UL installations.
WWW.DIYALARMFORUM.COM
Summary of Contents for Ademco VISTA-50P
Page 2: ...ii WWW DIYALARMFORUM COM ...
Page 12: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 2 4 WWW DIYALARMFORUM COM ...
Page 40: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 3 28 WWW DIYALARMFORUM COM ...
Page 48: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 4 8 WWW DIYALARMFORUM COM ...
Page 64: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 5 16 WWW DIYALARMFORUM COM ...
Page 78: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 6 14 WWW DIYALARMFORUM COM ...
Page 82: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 7 4 WWW DIYALARMFORUM COM ...
Page 84: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 8 2 WWW DIYALARMFORUM COM ...
Page 98: ...VISTA 50P VISTA 50PUL Installation and Setup Guide B 2 WWW DIYALARMFORUM COM ...
Page 100: ...VISTA 50P VISTA 50PUL Installation and Setup Guide C 2 WWW DIYALARMFORUM COM ...
Page 102: ...VISTA 50P VISTA 50PUL Installation and Setup Guide D 2 WWW DIYALARMFORUM COM ...
Page 110: ...WWW DIYALARMFORUM COM ...
Page 111: ...WWW DIYALARMFORUM COM ...