Section 5 – Data Field Descriptions
5-11
FIELD
TITLE and DATA ENTRIES
EXPLANATION
1*28
RF Transmitter Low Battery
Sound
0
= disarmed state only
1
= both armed and disarmed states
Select when the RF transmitter low-battery condition should display and
audible beep annunciate on the keypad.
Must be
1
for UL installations.
1*29
RF Transmitter Low Battery
Reporting
0
= disable
1
= enable
If enabled, the system sends a Trouble message for RF transmitter low-
battery condition to the central station.
NOTE:
The Trouble message will be sent for a transmitter supervision
failure, independent of this selection.
Must be
1
for UL.
1*30
RF Receiver Supervision Check-
in Interval
Enter
02-15
times 2 hours (4-30 hours).
00
= disable receiver supervision.
Select the check-in monitoring interval for the RF receiver(s).
Failure of a receiver to receive any RF signal within the time entered
results in the activation of the response type programmed for zone 990 for
the first receiver and zone 988 for the second receiver and their related
communication reports.
Maximum is 2 (4 hr) for UL installations.
1*31
RF Transmitter Check-in Interval
Enter
02-15
times 2 hours (4-30 hours).
00
= disable transmitter supervision.
Select the check-in monitoring interval for the RF transmitters.
Failure of an individual transmitter to send a supervision signal within
the time entered will result in a trouble response and related
communication report.
Maximum is 2 (4 hr) for UL.
1*33
TouchTone with Rotary Backup
0
= disable
1
= enable
If enabled, the system reverts to rotary dialing if communicator is not
successful in dialing using TouchTone DTMF on first attempt.
1*34
Communicator Split Reporting
0
= Split Reporting disabled
1
= Alarm, Alarm Restore, and Cancel
reports to primary, all others to secondary
2
= Open/Close and Test reports to
secondary, all other reports to primary
Select the type of split reporting for system communication.
NOTE:
See *51 for split/dual reporting combinations.
1*35
Alarm Code for Zones 65–72
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the
Programming Guide
for details.
1*36
ID Digit for Zones 65–72
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the
Programming Guide
for details.
1*37
Alarm Code for Zones 73–80
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the
Programming Guide
for details.
1*38
ID Digit for Zones 73–80
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the
Programming Guide
for details.
1*39
Supervisory and Restore Codes
for Zones 65–80
Enter
00-15
.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code
01-15
for each type of report. Enter
00
for no report.
NOTE:
Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *75 and *77).
1*40
Non-Alarm Report Codes (First
Digit)
Enter
00-15
.
This field has seven two-digit entries as follows: Arm STAY, Time/Date
set or Event Log Reset, Event Log 50% or 90% Full, Event Log Overflow,
Exit Error (Zone), Exit Error (User) and Recent Close. Enter the report
code
01-15
for each type of report. Enter
00
for no report.
WWW.DIYALARMFORUM.COM
Summary of Contents for Ademco VISTA-50P
Page 2: ...ii WWW DIYALARMFORUM COM ...
Page 12: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 2 4 WWW DIYALARMFORUM COM ...
Page 40: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 3 28 WWW DIYALARMFORUM COM ...
Page 48: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 4 8 WWW DIYALARMFORUM COM ...
Page 64: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 5 16 WWW DIYALARMFORUM COM ...
Page 78: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 6 14 WWW DIYALARMFORUM COM ...
Page 82: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 7 4 WWW DIYALARMFORUM COM ...
Page 84: ...VISTA 50P VISTA 50PUL Installation and Setup Guide 8 2 WWW DIYALARMFORUM COM ...
Page 98: ...VISTA 50P VISTA 50PUL Installation and Setup Guide B 2 WWW DIYALARMFORUM COM ...
Page 100: ...VISTA 50P VISTA 50PUL Installation and Setup Guide C 2 WWW DIYALARMFORUM COM ...
Page 102: ...VISTA 50P VISTA 50PUL Installation and Setup Guide D 2 WWW DIYALARMFORUM COM ...
Page 110: ...WWW DIYALARMFORUM COM ...
Page 111: ...WWW DIYALARMFORUM COM ...