• measure the textile in tension (see table below)
Manyard
Type
Ref
L Max
2 M
1005318 - 1005325
1005327 - 1006709
1009770 - 1009771
1009772 - 1009773
1009774 - 1013491
1013520 - 1014690
1014938
1 m 68 cm
1,75 M
1010470
1 m 46 cm
1,5 M
1005317 - 1005324
1011754 - 1013521
1003970 - 1014659
1 m 21 cm
In case of doubt, the lanyard should not be used, since the energy absorber was not designed to
stop more than one fall.
CLEARANCE
If there is a risk of falling or if the harness can only be anchored below the hook point, a lanyard
with an energy absorber must absolutely be used. Check before using an energy absorbing lanyard
and manyard that there is enough clearance under the user’s feet to avoid any collision with the
structure or the ground. With a mass of 100 kg and a fall factor situation of two (most unfavoura-
ble), the headroom D is the stop distance H (2L + 1.75 m) plus a supplementary distance of 1 m,
with length L (l energy absorber) Ex. For a lanyard with energy absorber where L=2 m, the
minimum clearance D=6.75 m.
PERIODIC INSPECTION
These instructions must be kept with the product. Use the identification card for recording the la-
belling information. The periodic inspection shall check the equipment’s effectiveness and
strength and is essential to guarantee the user’s safety.
This equipment must be examined, at least once a year, by a competent person and
in strict compliance with the manufacturer, the verification to be recorded on the
attached sheet and by affixing a self-adhesive dot on the product (see fig. 1) .The
legibility of the product labelling must be checked.
LIFESPAN OF THE PPE
The maximal life of PPE that is predominantly textile is evaluated as being 10 years after the date
of manufacture, however, the following factors may reduce the performance of the product and the
lifespan: incorrect storage, incorrect use, fall arrest, mechanical warping, contact with chemicals
(acids and alkalis), exposure to high temperatures > 60°C.
ANCHORAGE POINT
If possible, to be used with anchorage devices (conformed to the EN 795 standard) or structural
anchor. that is to say elements fixed to last, to a structure (wall, post…).
In all cases, check that the anchoring point:
• Has a minimum resistance of 12 kN,
• Is located above the operator,
• Is located within a vertical axis of the work area (maximum angle ±30°),
• Adapts perfectly to the equipment’s attachment device,
• Has no sharp edges.
MAINTENANCE AND STORAGE
Good maintenance and appropriate storage of your PPE will prolong the life of your product, while
guaranteeing your safety. The following recommendations must be strictly respected:
• The product should be cleaned with water and a mild soap. Never use acidic or basic solvents.
• Allow it to air dry in a well ventilated area, away from sources of heat. Store the harness away
from humidity and ultraviolet light.
L > L Max.
Fig. 1
12
Summary of Contents for 15.112.771
Page 1: ...Fall Protection CONNECTION LANYARD User Instruction Manual ...
Page 2: ...2 ...
Page 4: ...EN 354 EN 355 4 ...
Page 5: ...EN 355 5 ...
Page 6: ...6 ...
Page 7: ...7 ...
Page 8: ...EN 355 EN 354 EN 355 EN 354 EN 355 EN 354 8 ...
Page 91: ...1 3 2 4 5 6 1 3 2 4 5 6 1 3 2 4 5 6 1 3 2 4 5 6 1 3 2 4 5 6 ...
Page 94: ......
Page 95: ......