39
Mounting and Connection Instructions Reader series "luminAXS"
7.1.
Manual address allocation via central control unit
4
Enter the serial number of a new
plus the desired address when programming the central
reader
control unit. The
transmits the serial number plus the address to the
. If the
controller
reader
received serial number
the number defined in the reader,
reader
corresponds with
the
stores the
address.
Programming
Enter serial
number
of the operating unit
plus adress
EU
Panel
Serial number
+
address
Serial number
+
address
The address allocation mode must be
activated.
Hold an MIFARE data carrier in the reading
range. The
now transmits the
reader
serial
number to the
. The
controller
controller
allocates a free address to this number and
transmits
the
number
plus
the
serial
address back to the
. After a brief
reader
interval, the
stores the address
reader
permanently.
Acknowledgement:
After approx. 1 sec.
the LEDs indicate the allocated address
(see 7.1.3).
Serial number
Serial number
+
address
EU
Panel
allocates a free
address to the
number
serial
7.1.
Automatic address allocation with data carrier
5
7.1.6
Manual address allocation via IQ DeviceInstaller and configuration tool usb
Set up according to Sect. 4.2.
Enter the address in the configuration mode. The address is stored in the reader.
A
:
!
TTENTION A plausibility check is not possible
The address is stored in the reader.
If the reader is later connected with the EU/control panel, the entered address is then sent to the
EU/control panel together with the reader serial number and stored there.
The address can now be confirmed in the display mode (see 7.1.3)