Mounting and Connection Instructions Reader series "luminAXS"
4.2
User parameterisation with the configuration tool usb
4.2.1
Usage of the Configuration tool
Depending on the application of the reader, it may be necessary to change the standard parameters.
With the software tool
in combination with the
(Item
"IQ DeviceInstaller"
configuration tool usb
no. 027966), it is possible to parameterise the reader and perform a firmware update.
You can find the IQ DeviceInstaller incl. Programming Instructions on our homepage in the download
area.
-
No higher-level system is needed for the programming.
-
The programming can also be performed on readers with a Clock/Data interface. The readers
are able to receive data via these normally unidirectional interfaces.
During the programming the readers are switched to the RS-485 mode.
4.
Configuration
4.1
Standard programming in state of delivery
In delivery condition the reader has a standard programming that ensures the basic functioning of the
reader.
The
includes the following parameters:
standard programming
-
Light ring pale blue in sleep mode.
-
Button background lighting low brightness in sleep mode, bright for 5 seconds on detecting a data
carrier.
-
RS-485 is set to MIFARE readers.
IQ
Device
Installer
1
2
3
4
5
6
7
8
1
2
3
4
5
RS-485
USB
+12V DC
0 V
RS-485
Configuration tool USB
027966
PC/Laptop
red
blue
yellow
white
black
green
brown
pink
red
blue
yellow
white
black
Clock/Data
Interface converter
Functional principle: