HZ322 TrueZONE

 

1 69-2199—09

APPLICATION

ACCESSORIES

Table 1. Recommended Thermostats.

System

Thermostat

Single stage

TH1110D2009 (non-programmable)

TH4110U2005 (Programmable)

2H/1C  

conventional

TH6220U2000 (Programmable)

TH6220WF2006 (Programmable, Wi-Fi)

2H/2C  

conventional

TH6220U2000 (Programmable)

TH6220WF2006 (Programmable, Wi-Fi)

2H/1C heat pump TH4210U2002 (Programmable)

TH6210U2001 (Programmable)

All the above

TH6220U2000 (Programmable)

TH6220WF2006 (Programmable, Wi-Fi)

TH6320WF2003 (Programmable, Wi-Fi)

TH8321WF1001 (Programmable, Wi-Fi)

THX321WFS2001W (Programmable, Wi-Fi)

Wireless *

TH5320R1002

TH6320R1004

TH8320R1003

*  For RedLINK™ wireless devices, a THM4000 is required.

Table 2. Recommended Dampers.

Type

Damper

Round

Rectangular

Zone

Spring-open/

power-closed

ARD (8 VA)

ZD (8 VA)

Power-open/

power-closed

MARD/ 

RRD (2 VA)

Bypass

Constant  

pres sure   

regulating 

damper

CPRD (0 VA spring 

actuator)

Modulating 

automatic round 

damper

MARD (2 VA)

Table 3. Recommended Commercial Dampers.

Type

Actuation

Round

Zone

Power-open/power-closed

MARD

Bypass

Power-open/power-closed

MARD with SPC

Table 4. Maximum Dampers.*

Ambient Temp.

Maximum Damper VA per Zone

100°F (38°C)

28.8

160°F (71°C)

16.8

* Use an SDCR (Slave Damper Control Relay) for 

additional dampers.

  Maximum dampers per panel is limited by trans-

former size.

  Ensure transformer is large enough to power the 

panel (7.5 VA) and dampers.

Table 5. Accessories.

Accessory

Description

40 VA transformer*

AT140A1042*

75 VA transformer

AT175A1008

Discharge Air 

Temperature Sensor *

DATS C7735A1000*

SDCR**

Slave Damper Control 

Relay

Wireless Adapter***

THM4000R1000

Wireless Outdoor Air 

Temperature Sensor***

C7089R1013

Portable Comfort 

Control***

REM5000R1001

RedLINK Internet 

Gateway***

THM6000R7001

*   Included in HZ322K kit.

**  Use an SDCR (Slave Damper Control Relay) to 

add additional dampers to a zone to surpass the 

maximum Damper VA rating per Zone.

*** For RedLINK™ wireless devices, a THM4000 is 

required.

The HZ322 TrueZONE

®

 panel controls:

• 

Conventional gas, oil, or electric forced-air systems up to 2 stages heat and cool;

• 

Heat pump systems with single stage compressor and auxiliary heat, and two stage heat pumps with no 
auxiliary heat.

• 

2 or 3 forced-air zones with wired thermostats, or wireless thermostats using THM4000R wireless adapter.

Please refer to TrueZONE Panel Frequently Asked Questions form 50-9694 for operating details.
customer.resideo.com

Summary of Contents for TrueZONE HZ322

Page 1: ...HZ322 TrueZONE Zone Panel Professional Installation Guide HZ332 HEAT 1 HEAT 2 COOL 1 COOL 2 FAN PURGE EM HEAT EMERGENCY HEAT ZONE 1 ZONE 2 ZONE 3 69 2199 09...

Page 2: ...ondensing Temperature Ratings Shipping 20 F to 150 F 29 C to 66 C Operating 40 F to 165 F 40 C to 74 C Dimensions See Fig 1 Emissions Complies with FCC Class B part 15 requirements Read before install...

Page 3: ...imum Dampers Ambient Temp Maximum Damper VA per Zone 100 F 38 C 28 8 160 F 71 C 16 8 Use an SDCR Slave Damper Control Relay for additional dampers Maximum dampers per panel is limited by trans former...

Page 4: ...e and use the base as a template to drill mounting holes Attach the base to the wall stud roof truss or duct with appropriate screws not included Use two screws for attaching to a stud or roof truss o...

Page 5: ...ne panel To connect wire to the panel strip approximately 1 4 in of insulation and push wire into terminal To release wire press the button on to p of the terminal In retrofit applications trim end of...

Page 6: ...charge Air Temperature Installation Instructions Form Number 69 1521 5 Connect equipment as shown here and on page 5 and 6 6 C7735A1000 M28024 SENSOR DATS DATS 8 Connect a dedicated transform er as sh...

Page 7: ...22 HEAT 1 HEAT 2 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 EMERGENCY HEAT M1 M4 M6 R C W1 E W2 Y1 Y2 G O B L Zone 1 DAMPER THERMOSTAT M1 M4 M6 R C W1 E W2 Y1 Y2 G O B L Zone 2 DAMPER THERMO...

Page 8: ...520 72 7 21 25 7 50267 76 7 6 3 5 7 2 1 7 50 1 6 77 2 25 22 1 29 5 25 77 25 7 1 29 5 9 48 30 17 86 6 7 6 0 6285 2 7 25 8 5 1 0 5 1 7 803 5 1 7 50 1 6 25 7 7 0 5 5 66 3725 21 1 9 5 5 7 0 5 25 7 0 5 0...

Page 9: ...CONVENTIONAL NON HEAT PUMP THERMOSTATS OPTIONS TSTAT TIMER ZONES OFF ADVANCED CONFIG NO YES SAVE CHANGES NO YES COMPRESSOR STAGES 1 2 1 2 3 1 AUX HT ENABLED YES NO SET TO YES IF WIRELESS RADIO FREQUEN...

Page 10: ...mit DAT HIGH LIMIT 110 F 180 F 160 F 110 deg F 180 deg F High temperature limit DATS Low Limit DAT LOW LIMIT 30 F 60 F 40 F 30 deg F 60 deg F Low temperature limit OT Temp Enabled OT SENSOR NO YES Dis...

Page 11: ...il the Check out LED lights up Use the Adjust Setting and Next buttons to work through the checkout menu as listed below See the Configuration section on page 7 for instructions on using these buttons...

Page 12: ...be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the produ...

Reviews: