3
Setup options
1
From the Contractor Menu, highlight
Set Up
and press
OK
.
2
Press
s
or
t
to highlight the setting and press
OK
. Continue until
all settings have been configured.
3
When all settings are configured, you will be prompted to save
changes. Highlight
Yes
and press
OK
to save and exit. To exit setup
early by pressing
t
to highlight
EXIT
and press
OK
.
ISU # Description
Setting
1160
Temperature
indication scale
0 = Fahrenheit
1 = Celsius
2120
Heating system type
1 = Conventional forced air heat
2 = Heat pump
3 = Radiant heat
5 = None (cool only)
2140
Heating equipment
type
Conventional Forced Air Heat:
1 = Standard efficiency gas forced air
2 = High efficiency gas forced air
3 = Oil forced air
4 = Electric forced air
5 = Hot water fan coil
Heat Pump:
7 = Air to air heat pump
8 = Geothermal heat pump
Radiant Heat:
9 = Hot water radiant heat
12 = Steam
2160
Reversing valve O/B
0 = O (O/B on cool)
1 = B (O/B on heat)
2180
Cool stages /
compressor stages
0, 1, 2
2200
Heat stages /
backup heat stages
Heat stages: 0, 1, 2
Backup heat stages: 0, 1
2220
Fan operation in heat
0 = No fan
1 = Equipment controls fan
2 = Thermostat controls fan
2240
Backup heat type
31 = Electric forced air
32 = Gas/Oil Forced air (or Fossil forced air)
2260
External Fossil Fuel
Kit
0 = Thermostat controls backup heat
1 = External Fossil Fuel Kit controls backup
heat
3120
Staging control
- backup heat
differential
Comfort
2.0°F to 15.0°F from setpoint (in 0.5°F
increments)
1.0°C to 7.5°C from setpoint (in 0.25°C
increments)
3140
Backup heat upstage
timer
Off
30, 45, 60, 75, 90 minutes
2, 3, 4, 5, 6, 8, 10, 12, 14, 16 hours
3160
Compressor lockout /
balance point
Off
5°F to 60°F (in 5°F increments)
-15.0°C to 15.5°C (in 2.5°C or 3.0°C
increments)
3180
Backup heat lockout
Off
5°F to 65°F (in 5°F increments)
-15.0°C to 18.5°C (in 2.5°C or 3.0°C
increments)
3200
Cool cycles per hour
1 - 6
3220
Cool cycles per hour
- stage 2
1 - 6
3240
Heat cycles per hour
1 - 12
3260
Heat cycles per hour
- stage 2
1 - 12
3280
Backup heat cycles
per hour
1 - 12
4120
Adaptive intelligent
recovery
0 = No
1 = Yes
ISU # Description
Setting
4160
Minimum setpoint
(Note: Setting applies
to both heat and cool
setpoints)
50°F to 99°F
10.0°C to 37.0°C
4220
Maximum setpoint
(Note: Setting applies
to both heat and cool
setpoints)
40°F to 90°F
4.5°C to 32.0°C
8100
Humidifier type
0 = None
1 = Steam
2 = Bypass or fan powered
8120
Humidification -
window protection
0 = Off
1 = On
8140
Humidification
control
0 = Humidify only when heat is On
1 = Humidify only when fan is On
2 = Humidify on demand: Thermostat
controls fan
3 = Humidify on demand: Humidifier controls
fan
9100
Dehumidification
equipment
0 = None
1 = A/C with low speed fan
2 = A/C with high speed fan
4 = Whole house dehumidifier
9140
Dehumidification
equipment setup
0 = Normally open
1 = Normally closed
9160
Dehumidification -
overcooling limit
0, 1, 2, 3°F
0.0, 0.5, 1.0, 1.5°C
9180
Dehumidifier fan
control
0 = Thermostat controls fan
1 = Equipment controls fan
10100 Ventilation type
0 = None
1 = ERV / HRV
2 = Passive (fan only)
3 = Fresh air damper
10160 Ventilation fan
control
0 = Thermostat controls fan
1 = Equipment controls fan
10240 Ventilation percent
on time
10% to 100% (in 10% increments)
10280 Ventilation low
temperature lockout
Off
-20°F to 40°F (in 5°F increments)
-29.0°C to 4.5°C (in 2.5°C or 3.0°C
increments)
10300 Ventilation high
temperature lockout
Off
80°F to 110°F (in 5°F increments)
26.5°C to 43.5°C (in 2.5°C or 3.0°C
increments)
10320 Ventilation high dew
point lockout
Off
65°F to 85°F (in 5°F increments)
18.5°C to 29.5°C (in 2.5°C or 3.0°C
increments)
11100 Home heat setpoint
40°F to 90°F
4.5°C to 32.0°C (in 0.5°C increments)
11120 Home cool setpoint
50°F to 99°F
10.0°C to 37.0°C (in 0.5°C increments)
11140 Setpoint for away
mode
0 = Away setpoints
1 = Smart temperature setpoints
11160 Away heat setpoint
40°F to 90°F
4.5°C to 32.0°C (in 0.5°C increments)
11180 Away cool setpoint
50°F to 99°F
10.0°C to 37.0°F (in 0.5°C increments)
14020 Temperature display
offset
-3°F to 3°F
14025 Humidity % offset
-12% RH to 12% RH