CRANKCASE
13-14
CONNECTING ROD BIG END OIL
CLEARANCE
Clean all oil from the crank pin and connecting rod big
end surface.
Place a piece of plastigauge on the crank pin, install the
connecting rod upper and the connecting rod lower, and
tighten the connecting rod bolts to the specified torque.
Do not rotate the crankshaft while the plastigauge is in
place.
Remove the connecting rod and measure the
plastigauge.
If the clearance is more than the service limit, inspect
the connecting rod big end I.D. and the crank pin
O.D.(page 13-13).
If necessary replace the part that is not within the
service limit and reinspect the clearance.
CRANKSHAFT RUNOUT
Set the crankshaft on V-blocks and measure the runout
using a dial indicator.
If the measured runout is more than the service limit,
replace the crankshaft (page 13-5).
TORQUE: 14 N·m (1.4 kgf·m, 10 lbf·ft)
STANDARD:
0.040 – 0.064 mm
(0.0016 – 0.0025 in)
SERVICE LIMIT:
0.12 mm (0.005 in)
SERVICE LIMIT:
0.1 mm (0.004 in)
16 mm
(0.6 in)
WT30XK4:
16 mm (0.6 in)
WT40XK3
17 mm (0.7 in)
61YG1000.book 14 ページ 2012年2月20日 月曜日 午後2時43分
Summary of Contents for WT30XK4
Page 11: ...MEMO 61YG1000 book 6...
Page 35: ...MEMO 61YG1000 book 14...
Page 42: ...5 1 5 dummytext 5 COVER FAN COVER REMOVAL INSTALLATION 5 2 61YG1000 book 1...
Page 59: ...IGNITION SYSTEM 8 2 IGNITION SYSTEM TOOL Puller collar set 07APC ZY1A100 61YG1000 book 2...
Page 67: ...MEMO 61YG1000 book 10...
Page 75: ...PUMP 10 2 PUMP TOOL Vacuum gauge 07APJ YB3A100 61YG1000 book 2...
Page 81: ...MEMO 61YG1000 book 8...
Page 95: ...MEMO 61YG1000 book 12...
Page 117: ...MEMO 61YG1000 book 22...
Page 121: ...MEMO 61YG1000 book 4...
Page 122: ...15 1 15 dummytext 15 WIRING DIAGRAM WIRING DIAGRAM 15 2 61YG1000 book 1...