−
−
+
+
+
+
−
−
−
+
−
−
+
−
+
63
Battery charging
(ETS, EWS)
BATTERY
BATTERY HOLDER NUT (2)
POSITIVE (
)
CABLE
NEGATIVE (
)
CABLE
NEGATIVE (
)
TERMINAL
POSITIVE (
)
TERMINAL
BATTERY
BATTERY
FILLER
CAPS
BATTERY CHARGER
NEGATIVE (
) CABLE
BATTERY CHARGER
POSITIVE (
) CABLE
Battery charger which is commercially availlablae for 12 V batteries
can be used to charge the battery:
Battery service
If the snowblower will be stored for an extended period, remove the
battery and store in a cool, dry place with the negative terminal
disconnected from the battery. Recharge it every 6 months.
Check the battery electrolyte level (see page
).
Remove the negative (
) cable from the battery negative (
)
terminal; then remove the positive (
) cable from the battery
positive (
) terminal.
Loosen the battery holder nuts and remove the battery.
Remove the battery filler caps, and connect the battery charger
positive (
) cable to the battery positive (
) terminal; then
connect the battery charger negative (
) cable to the battery
negative (
) terminal.
Charge the battery:
5
10 hours at 1.2 A.
Install the battery in the reverse order of removal.
6.
(1)
(2)
(3)
(4)
(5)
(6)
28
07/05/31 14:46:28 3C768600_067