19
Voltage Selector Switch
120V ONLY Position
120V/240V Position
Switch Position
Receptacle
Total Current
Available
Power Producing
Circuit
Set of
Receptacles
Available Power
The power available to each receptacle depends on the position of the
voltage selector switch.
When the voltage selector switch is in the 120V ONLY position, you
do not need to spread the load over the receptacles. You must,
however, make sure the load on any receptacle does not exceed its
available power shown in the preceding table and the total load does
not exceed 37.5 amps.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 18.8 amps.
120V ONLY
120V/240V
1
2
3
4
5
1
2
3
4-5
18.8A
18.8A
1
2
1
3
5
2
4
30A at 120V
20A at 120V
20A at 120V
20A at 120V
None
18.8A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 240V