PETROL GENERATOR

EN 

OWNERS MANUAL

PPG-2800, PPG-3750

Summary of Contents for PPG-2800

Page 1: ...CLICK TO CHANGE TEXT 1 PETROL GENERATOR EN OWNERS MANUAL PPG 2800 PPG 3750 ...

Page 2: ...l are supplied by Parker Products Ltd to help you with the operation and maintenance of the product The information contained in this manual was accurate at the time of production however Parker Products Ltd may make modifications to the product without notification GENERAL SAFETY RULES 4 SAFETY SYMBOLS 5 PRODUCT FEATURES 6 9 BEFORE USING THE GENERATOR 10 11 WHEEL ASSEMBLY PPG 3750 12 15 CHECK ENG...

Page 3: ...quids to clean the generator NEVER allow the generator air vents to become blocked ADDITIONAL SAFETY RULES FOR GENERATORS ALWAYS ensure the applied load does not exceed the generator rating Overloading the generator is dangerous and could cause serious damage ALWAYS disconnect the generator when carrying out any maintenance ALWAYS ensure the generator reaches operating speed before connecting a lo...

Page 4: ...UCT FEATURES VOLTAGE SWITCH PRODUCT FEATURES FUEL LEVEL INDICATOR OIL ALARM BREAKER SWITCH VOLT METER DC 12V RESET 6 5HP ENGINE COIL PLUG CAP FUEL TANK CHOKE LEVER OIL DRAIN PLUG CARBURETTOR 110 230V AC SOCKETS ...

Page 5: ...8 9 PRODUCT FEATURES PRODUCT FEATURES EXHAUST OPEN FRAME ENGINE COOLING TIN RECOIL FUEL TAP ENGINE DAMPERS AIR FILTER CONTROL PANEL ...

Page 6: ...to an earth point using the earth terminal Fig1 1 INSPECT THE GENERATOR 10 BEFORE USING THE GENERATOR 11 BEFORE USING THE GENERATOR WARNING Ensure there is adequate fuel in the tank when using the generator Running out of fuel or stopping the engine suddenly with a load connected could cause serious damage i Fig 1 Check the generator is not damaged and all components are in good working order befo...

Page 7: ...e the axle into the axle housing located on the frame of the generator Make sure the threaded end is pointing outward away from the generator 1 1 INSPECT THE WHEEL KIT Check the Wheel Kit is not damaged and all components are in good working order before use Regular periodic inspection is required to ensure the Wheel kit is suitable for the task This wheel kit is only supplied as an optional extra...

Page 8: ...e that the wheel is positioned all the way back on the axle 2 The rubber feet extension will ensure that the generator has a level firm and sturdy base Make sure the generator is kept level whilst in use RUBBER FEET EXTENSION ASSEMBLY First fit the rubber feet to the rubber feet extension bar Then fit the rubber feet extension bar with the rubber feet attached to the bottom of the generator frame ...

Page 9: ... end of the generator This is the lightest part of the generator and the handle location ensures that the user lifts the lightest load possible when manoeuvring Ensure the handles are in the down position to prevent any tripping hazards in the working area when in use 2 HANDLE FUNCTION The wheels of the PPG 3750 are located at the engine end of the generator This is the heaviest part of the genera...

Page 10: ... WARNING Always refuel in a well ventilated area away from any heat sources WARNING Allow the unit to cool down before refuelling WARNING Do not leave fuel within the reach of children Take out the dipstick and clean with a cloth Put the dipstick back into the oil filler tube and then remove it again Do not screw it in all the way back in when doing this If the oil is below the L level on the dips...

Page 11: ...r to the off position 1 SET BREAKER SWITCH SET CHOKE Pull the starting handle lightly until you start to feel resistance and then pull up sharply to start the generator Once the engine has warmed up set the choke lever to the RUN position 5 PULL STARTER RECOIL 6 Turn the engine switch to the ON position 4 SWITCH ENGINE ON SET CHOKE WARNING Once the generator has started release the starting handle...

Page 12: ...UTION any device which contains an inductive load e g devices that contain a motor may required more current on start up If the DC overload protector activates wait for a few minutes and then press the reset button shown on the right 2 DC OVER LOAD PROTECTOR Connect the battery charging leads to the battery Clamp the red wire to the positive terminal and the black wire to the negative terminal Con...

Page 13: ... disposal site WARNING Do not throw away used engine oil with your domestic trash or down drains and sinks NOTE Drain the engine oil when the engine is warm this will ensure the oil flows out quicker CAUTION Prolonged exposure to used engine oil is dangerous always wash your hands thoroughly after handling used engine oil Replace the oil plug and its seal ring Fill the crankcase with engine oil to...

Page 14: ...lace drain screw 2 DRAIN FUEL 3 Place an empty container under the carburettor Carefully unscrew the drain screw on the bottom of the carb gold bowl which is at a 45 degree angle 1 REMOVE CARB DRAIN SCREW REPLACE DRAIN SCREW NOTE Always place a suitable container underneath the carburettor when draining to prevent any spillages WARNING Always drain fuel in a well ventilated area away from any heat...

Page 15: ...AP CAUTION Allow the engine to cool before removing the spark plug CAUTION Do not use the generator without the air filter fitted this can damage the generator WARNING Do not use inflammable solvents or petrol to clean the air filter Remove the air filter element Make sure that the air filter is clean and not damaged If the filter is dirty wash the filter in warm water a mild detergent and rinse L...

Page 16: ...REASSEMBLE VALVE FILTER PROBLEM POSSIBLE CAUSE SOLUTION GENERATOR WILL NOT START Engine switch is Off Set Engine switch to On Out of fuel Fill fuel tank Engine oil low Add engine oil Spark plug wire disconnected Connect spark plug wire Bad spark plug Replace Clogged fuel filter Contact ParkerBrand GENERATOR FAILS TO GENERATE ELECTRICITY Device you are trying to power is faulty Make sure the device...

Page 17: ...FLANGE BOLT 56 SPRING WASHER 69 FRAME STAND 7 BUSH 19 HEX FLANGE BOLT 31 RECTIFIER 43 COLLAPSIBLE 57 FLAT WASHER 70 FLAT WASHER 8 FUEL TANK CUSHION 20 MUFFLER SEAL 32 HEX FLANGE BOLT 44 PANEL 58 HEX FLANGE BOLT 71 NUT 9 FUEL TANK 21 MUFFLER ASSEMBLY 33 CARBON BRUSH ASSEMBLY 45 SWITCH 59 PANEL 72N GUARD BOARD 10 FUEL TANK SWITCH FILTER SCREEN 22 SPRING WASHER 34 CONNECTION BLOCK 46 POWER INDICATOR ...

Page 18: ...VER 96 INTAKE WASHER 8 BOLT 22 PISTON RING ASSEMBLY 36 SPEED ADJUSTING SHAFT BUSH 50 CRANKCASE 69 FAN COVER 83 HEX FLANGE BOLT 97 CARBURETTOR HEAT INSULATOR 9 LEVER BRACKET 23 PISTON PIN 37 OIL SENSOR ASSEMBLY 51 OIL DRAIN BOLT WASHER 70 ONE WAY CONDUCTOR ASSY 84 GOVERNER ROD 98 OUT CARBURETTOR WASHER 10 VALVE HEAD CAP 24 PISTON PIN CIRCLIP 38 NUT 52 OIL DRAIN BOLT 71 HEX FLANGE BOLT 85 TRIMMING S...

Page 19: ...ed Weight kg 40 Engine Oil Capacity L 0 6 Guaranteed Sound Power LWA dB 65 All information correct at time of printing PPG 3750 TECHNICAL SPECIFICATIONS Type Petrol air cooled 4 Stroke OHV single cylinder Rated Frequency Hz 50 Displacement cm 210 Rated Voltage V 220 230 Max Power Output hp rpm 7 0 3000 Rated Power kW kVa 2 8 3 5 Ignition Type Mag Maximum Power kW kVA 3 0 3 75 Start System Recoil L...

Page 20: ... Certificate number N8MA 17 07 93525 026 Manufacturer s authorised representative within the EC Parker Products Ltd Richmond Park Richmond Road Louth LN11 0FU Technical file complied by Parker Products Ltd Being the responsible person appointed by the manufacturer Signed Date 25 06 19 Name Jason Parker Position Managing Director Company Parker Products Ltd DECLARATION OF CONFORMITY GUARANTEE Parke...

Page 21: ...WWW PARKERBRAND COM PPG 2800 PPG 3750 Rev 1 1 Oct 2019 ...