![Honda BF100D Owner'S Manual Download Page 117](http://html1.mh-extra.com/html/honda/bf100d/bf100d_owners-manual_2157724117.webp)
115
TAKING CARE OF UNEXPECTED PROBLEMS
FUSES
Electric Starter Will Not
Operate
The 10 A, 15 A, and 30 A main fuses
protect the electric starter relay and
related circuits.
The 10 A (No. 2) main fuse protects
the ignition switch and related
circuits.
If this fuse blows, the engine will not
start or run, and the power trim/tilt
switch will not activate the trim/tilt
mechanism.
Battery Will Not Charge
A 70 A ACG fuse protects the
alternator circuit. If the ACG fuse
blows, the engine will not charge the
battery. Refer to p.116.
Fuse Replacement
Disconnect the battery cable at the
battery negative (-) terminal before
replacing the fuse.
Failure to do so may cause a short
circuit.
Main Fuse
1. Stop the engine and disconnect the
battery cable.
2. Remove the engine cover.
3. Remove the fuse case lid.
FUSE CASE LID
SPARE FUSES
(10 A, 15 A, 30 A)
FUSES
(10 A,
15 A,
30 A)
10 A (No. 2) MAIN FUSE
31ZY96300.book 115 ページ 2013年10月21日 月曜日 午前9時25分