7
HomewerksWW.com
NEW CONSTRUCTION INSTALLATION INSTRUCTIONS
5. Remove the wiring cover. Pull the house wires through the
wiring cover hole. Using the attached quick connectors,
connect 120v house wiring to the fan as shown in the wiring
diagram on page 5. 12-18 AWG is the smallest conductor that
should be used for branch circuit wiring.
Carefully push the connected wires back into the wiring box
housing. Reattach the wiring box cover.
CAUTION:
If the house electrical wires do not match the
colors from the fan wiring diagram on page 5, you must
determine what each house wire represents before
connecting. You may need to consult an electrical
contractor to determine safely.
Wiring
cover
Wiring
cover
House
wires
Quick
connector
Product
wires
5
6. Connect a 4 in. circular duct (not included) and vent to the
outside. Secure it with duct tape (not included) or a clamp
(not included) to make the connection secure and airtight.
Finish ceiling work. Ceiling hole should be aligned with edge
of the fan housing (A).
A
6
7. Plug the connector attached to the grille (B) into the connector
on the fan housing (A).
7
A
B
Connector
8. Attach the grille (B) by pinching the mounting springs
and inserting into the narrow rectangular slots in the fan
housing (A).
Turn on the power source. Check the fan for any abnormal
sound or vibration.
8
Mounting
spring
Mounting
spring