5
HomewerksWW.com
PREPARATION
Before removing your current ventilation unit, verify your switch box on the wall has the required supply wires
necessary for this installation. These supply wires are power/black and neutral/white (refer to right side of wiring
diagram below) at the switch. If you do not see both of these wires, consult a licensed electrician.
Check area above installation location to be sure that wiring can run to the planned location and that duct work can be run
and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
You may need the help of a second person to install this fan; one person on the attic side and one on the room side.
Note:
I
nstallation may vary depending on how the previous bath fan was installed. Supplies necessary
for the installation of your bath fan are not all included; however, most are available at your local home improvement or
hardware store.
DIMENSIONS REQUIREMENTS
Ceiling
Opening (L)
Ceiling
Opening (W)
Ceiling
Opening (H)
Housing
Dimension (L)
Housing
Dimension (W)
Housing
Dimension (H)
7-3/4 in.
7-1/2 in.
7-5/16 in.
7-1/2 in.
7-1/4 in.
7 in.
WIRING DIAGRAM
All wiring must be connected for full functionality. Do not use metal wall plate with switch.