41
Hazard information
The Wired Access Point is part of the building
installation. The relevant national standards and
directives must be taken into consideration
during planning and set-up. The Wired Access
Point is intended for operation within the
Homematic IP Wired bus only. The Homematic IP
Wired bus is a SELV power circuit. The power
supply of the building installation and the
Homematic IP Wired bus have to be laid
separately. Common cable routing for power
supply and the Homematic IP Wired bus in
installation and junction boxes is not permitted.
The required isolation for power supply of the
building installation to the Homematic IP Wired
bus must be observed at all times. Non-
compliance with the installation instructions can
cause fire or introduce other hazards.
The 24 V supply voltage
(B)
, the Ethernet cable
(F)
as well as Ethernet or telecommunication lines of
the Homematic IP Wired bus that are connected
to the bus connections
(J
and
G)
are SELV power
circuits. These wires must be routed separately
from mains voltage cables by measures for se-
cure separation (e.g. with horizontal and vertical
barrier strips).