56
Start-up
•
Select suitable tool, measuring equipment and, if
necessary, personal safety equipment;
•
Evaluation of measuring results;
•
Selection of electrical installation material for safe-
guarding shut-off conditions;
•
IP protection types;
•
Installation of electrical installation material;
•
Type of supply network (TN system, IT system, TT
system) and the resulting connecting conditions
(classical zero balancing, protective earthing, required
additional measures etc.).
For installing the floor heating controller into a
power distribution panel it has to be mounted in
accordance with VDE 0603, DIN 43871 (low-volt-
age sub-distribution board), DIN 18015-x. In this
case, the installation must be made on a mount-
ing rail (DIN rail) according to EN50022. Installa-
tion and wiring have to be performed according
to VDE 0100 (VDE 0100-410, VDE 0100-510 etc.).
Please consider the technical connection re-
quirements (TAB) of your energy supplier.
Please note the insulation stripping length of the
conductor to be connected, indicated on the de-
vice.