33
Start-up
• Switch off the fuse of the power circuit.
• Connect the switched phase conductors for con-
necting terminals 1 and 2 to the motor as follows
(
see fig. 2
):
- Connecting terminal 2
(C)
: “Up”
- Connecting terminal 1
(D)
: “Down”
• Connect the phase conductor to connecting ter-
minal L
(E)
(
see fig. 2
).
• Connect the neutral conductor to connecting
terminal N
(F)
(
see fig. 2
).
• Connect an external shutter push-button to con-
necting terminal S1 and S2 (
see fig. 2
):
- Connecting terminal S1
(G)
: “Down”
- Connecting terminal S2
(H)
: “Up”
• Connect the neutral conductor of the motor to
the neutral conductor of the house installation.
• Connect the phase connection of the shutter
push-button with the phase conductor of the
house installation.
• Fix the actuator to an appropriate surface-mount-
ing box (e.g. Abox 025 or Abox 040) (
see fig. 3
).
• Fix the actuator to the holding mandrel using the
fixing lug. Screw the actuator if required.
• Close the surface-mounting box using the corre-
sponding cover.
• Switch the fuse of the power circuit on again, to
activate the teach-in mode of the device (see „5.3
Teaching-in“ on page 34).