background image

30

Start-up

Please note! Only to be installed by persons with 
the relevant electro-technical knowledge and 
experience!*

Incorrect installation can put
• 

your own life at risk;

• 

and the lives of other users of the electrical system.

Incorrect installation also means that you are running the 
risk of serious damage to property, e.g. because of a fire. 
You may be personally liable in the event of injuries or 
damage to property.

Contact an electrical installer!

*

Specialist knowledge required for installation:

The following specialist knowledge is particularly important during 
installation:

• 

The “5 safety rules” to be used: 
Disconnect from mains; Safeguard from switching on 
again; Check that system is deenergised; Earth and short 
circuit; Cover or cordon off neighbouring live parts;

• 

Select suitable tool, measuring equipment and, if neces-
sary, personal safety equipment;

• 

Evaluation of measuring results;

• 

Selection of electrical installation material for safeguard-
ing shut-off conditions;

• 

IP protection types;

• 

Installation of electrical installation material;

• 

Type of supply network (TN system, IT system, TT sys-
tem) and the resulting connecting conditions (classical 
zero balancing, protective earthing, required additional 
measures etc.).

Summary of Contents for HmIP-FROLL

Page 1: ...beitet werden Es ist möglich dass die vorliegende Anleitung noch drucktech nische Mängel oder Druckfehler aufweist Die Angaben in dieser Anleitung werden jedoch regelmäßig überprüft und Korrekturen in der nächsten Ausgabe vorgenommen Für Fehler technischer oder drucktechnischer Art und ihre Folgen übernehmen wir keine Haftung Alle Warenzeichen und Schutzrechte werden anerkannt Printed in Hong Kong...

Page 2: ...2 3 ...

Page 3: ...se 7 5 2 Installation 9 5 2 1 Installation in einer Unterputzdose 9 5 2 2 Installation in einer Aufputzdose 11 5 3 Anlernen 12 6 Bedienung 14 7 Fehlerbehebung 14 7 1Befehl nicht bestätigt 14 7 2 Duty Cycle 15 7 3 Fehlercodes und Blinkfolgen 16 8 Wiederherstellung der Werkseinstellungen 17 9 Wartung und Reinigung 18 10 Allgemeine Hinweise zum Funkbetrieb 19 11 Technische Daten 20 ...

Page 4: ...te Symbole Achtung Hier wird auf eine Gefahr hingewiesen Hinweis Dieser Abschnitt enthält zusätzliche wichtige Informationen 2 Gefahrenhinweise Öffnen Sie das Gerät nicht Es enthält keine durch den Anwender zu wartenden Teile Das Öffnen birgt die Gefahr eines Stromschlages Lassen Sie das Gerät im Fehlerfall von einer Fachkraft prüfen Aus Sicherheits und Zulassungsgründen CE ist das eigenmächtige U...

Page 5: ...elastungen aus Das Gerät ist kein Spielzeug Erlauben Sie Kindern nicht damit zu spielen Lassen Sie das Verpa ckungsmaterial nicht achtlos liegen Plastikfolien tüten Styroporteile etc können für Kinder zu einem gefährlichen Spielzeug werden Bei Sach oder Personenschäden die durch un sachgemäße Handhabung oder Nichtbeachten der Gefahrenhinweise verursacht werden über nehmen wir keine Haftung In solc...

Page 6: ...en Schlages am Gerät schalten Sie bitte die Netz spannung frei Sicherungsautomat abschalten Bei Nichtbeachtung der Installationshinweise können Brand oder andere Gefahren entstehen Beachten Sie beim Anschluss an die Geräteklem men die hierfür zulässigen Leitungen und Lei tungsquerschnitte Die an den Relaisausgängen angeschlossenen Verbraucher müssen über eine ausreichende Iso lierung verfügen Beac...

Page 7: ...bgesichert sein Installationsvor schriften lt VDE 0100 bzw HD384 oder IEC 60364 müssen beachtet werden Der Leitungs schutzschalter muss für den Benutzer leicht er reichbar und als Trennvorrichtung für das Gerät gekennzeichnet sein Vor dem Anschließen des Aktors muss die Siche rung im Sicherungskasten herausgenommen werden Das Gerät ist nur für den Einsatz in wohnungs ähnlichen Umgebungen geeignet ...

Page 8: ...ch betriebene Behänge automa tisch hoch bzw herunterfahren Die Bedienung der Rollläden bzw Markisen erfolgt ganz bequem über einen externen Taster per Funk Fernbedie nung oder über die Homematic IP App Geräteübersicht s Abbildung 1 A Systemtaste Resettaste und LED B Fixieröse C Anschlussklemme für 2 Motor Hoch D Anschlussklemme für 1 Motor Runter E Anschlussklemme für L Außenleiter F Anschlussklem...

Page 9: ... betreiben Welcher Funktionsumfang sich innerhalb des Systems im Zusammenspiel mit weiteren Komponenten ergibt entnehmen Sie bitte dem Homematic IP Anwenderhandbuch Alle technischen Dokumente und Updates finden Sie stets aktuell unter www eQ 3 de 5 Inbetriebnahme 5 1 Installationshinweise Bitte lesen Sie diesen Abschnitt erst vollständig bevor Sie mit der Installation beginnen Bitte notieren Sie s...

Page 10: ...allation sind insbesondere folgende Fachkenntnisse er forderlich Die anzuwendenden 5 Sicherheitsregeln Freischalten gegen Wiedereinschalten sichern Spannungsfreiheit feststellen Erden und Kurzschließen benachbarte unter Spannung stehende Teile abdecken oder abschranken Auswahl des geeigneten Werkzeuges der Messgeräte und ggf der persönlichen Schutzausrüstung Auswertung der Messergebnisse Auswahl d...

Page 11: ...uerschnitte zum Anschluss an den Rollladenaktor sind Starre Leitung mm2 Flexible Leitung mit und ohne Aderendhülse mm2 0 75 1 50 0 75 1 50 5 2 Installation Sie haben die Möglichkeit den Rollladenaktor in einer Unterputzdose oder in einer Aufputzdose zu installieren 5 2 1 Installation in einer Unterputzdose Für die Installation des Rollladenaktors in einer Unter putzdose gehen Sie wie folgt vor Sch...

Page 12: ...ssklemme S1 und S2 an s Abbildung 2 Anschlussklemme S1 G Runter Anschlussklemme S2 H Hoch Schließen Sie den Neutralleiter des Motors an den Neutralleiter der Hausinstallation an Verbinden Sie den Phasenanschluss des Rollla dentasters mit dem Außenleiter der Hausinstal lation Setzen Sie den Aktor in eine geeignete Unter putzdose Sie können die Fixieröse B bei Bedarf entfernen Schließen Sie die Unte...

Page 13: ... an s Abbildung 2 Schließen Sie den Neutralleiter an die Anschluss klemme N F an s Abbildung 2 Schließen Sie den externen Rollladentaster wie folgt an die Anschlussklemme S1 und S2 an s Abbildung 2 Anschlussklemme S1 G Runter Anschlussklemme S2 H Hoch Schließen Sie den Neutralleiter des Motors an den Neutralleiter der Hausinstallation an Verbinden Sie den Phasenanschluss des Rollla dentasters mit ...

Page 14: ...omematic IP App ein um weitere Homematic IP Geräte im System nutzen zu kön nen Ausführliche Informationen dazu finden Sie in der Bedienungsanleitung des Access Points Sie können das Gerät sowohl an den Access Point als auch an die Homematic Zentrale CCU2 anler nen Weitere Informationen dazu entnehmen Sie bitte dem Homematic IP Anwenderhandbuch zu finden im Downloadbereich unter www eQ 3 de Damit d...

Page 15: ...r Home matic IP App Zur Bestätigung geben Sie in der App die letzten vier Ziffern der Gerätenummer SGTIN ein oder scannen Sie den QR Code Die Gerätenummer finden Sie auf dem Aufkleber im Lieferumfang oder direkt am Gerät Warten Sie bis der Anlernvorgang abgeschlossen ist Zur Bestätigung eines erfolgreichen Anlernvor gangs leuchtet die LED grün Das Gerät ist nun einsatzbereit Leuchtet die LED rot v...

Page 16: ...e Richtung bis Sie die Taste wieder loslassen oder die Endposition der Rolllä den oder Markise erreicht ist 7 Fehlerbehebung 7 1 Befehl nicht bestätigt Bestätigt mindestens ein Empfänger einen Befehl nicht leuchtet zum Abschluss der fehlerhaften Übertragung die LED rot auf Grund für die fehlerhafte Übertragung kann eine Funkstörung sein s 9 Allgemeine Hinweise zum Funkbetrieb auf Seite 19 Die fehl...

Page 17: ...des 1 Limits nicht mehr senden bis diese zeitliche Begrenzung vorüber ist Gemäß dieser Richtlinie werden Homematic IP Geräte zu 100 normenkonform entwickelt und produziert Im normalen Betrieb wird der Duty Cycle in der Regel nicht erreicht Dies kann jedoch in Einzelfällen bei der Inbetriebnahme oder Erstinstallation eines Systems durch vermehrte und funkintensive Anlernprozesse der Fall sein Eine ...

Page 18: ...nes Leuchten Vorgang bestätigt Sie können mit der Bedienung fort fahren Kurzes oranges Blinken alle 10 s Anlernmodus aktiv Geben Sie die letz ten vier Ziffern der Geräte Seriennum mer zur Bestätigung ein s 5 3 Anlernen auf Seite 12 1x langes rotes Leuchten Vorgang fehl geschlagen oder Duty Cycle Limit erreicht Versuchen Sie es erneut 7 1 Befehl nicht bestätigt auf Seite 14 oder 7 2 Duty Cycle auf ...

Page 19: ...r Werkseinstellungen Die Werkseinstellungen des Gerätes können wie derhergestellt werden Dabei gehen alle Einstel lungen verloren Um die Werkseinstellungen des Rollladenaktors wieder herzustellen gehen Sie wie folgt vor Drücken Sie für 4 s mit einem VDE Schrauben dreher auf die Systemtaste A bis die LED schnell orange zu blinken beginnt Lassen Sie die Systemtaste wieder los Drücken Sie die Systemt...

Page 20: ...eräts unbedingt die Netzspannung frei Sicherungsautomat abschal ten Arbeiten am 230 V Netz dürfen nur von ei ner Elektro Fachkraft nach VDE 0100 erfolgen Reinigen Sie das Gerät mit einem weichen sau beren trockenen und fusselfreien Tuch Für die Entfernung von stärkeren Verschmutzungen kann das Tuch leicht mit lauwarmem Wasser an gefeuchtet werden Achten Sie darauf dass keine Feuchtigkeit in das Ge...

Page 21: ...rogeräte Die Reichweite in Gebäuden kann stark von der im Freifeld abweichen Außer der Sendeleistung und den Empfangseigenschaften der Empfänger spielen Umwelteinflüsse wie Luftfeuchtigkeit neben baulichen Gegebenheiten vor Ort eine wichtige Rolle Hiermit erklärt die eQ 3 AG Maiburger Str 29 26789 Leer Deutschland dass der Funkanlagentyp Home matic IP HmIP FROLL der Richtlinie 2014 53 EU ent spric...

Page 22: ...erschnitt starre und flexible Leitung 0 75 1 5 mm Installation nur in Schalterdosen Gerätedosen gemäß DIN 49073 1 oder Verbindungsdosen Aufputzdosen gemäß DIN 60670 1 Schutzart IP20 Schutzklasse II Umgebungstemperatur 10 bis 55 C Abmessungen B x H x T 54 x 33 x 41 mm Gewicht 40 g Funk Frequenzband 868 0 868 6 MHz 869 4 868 65 MHz Maximale Funk Sendeleistung 10 dBm Empfängerkategorie SRD category 2...

Page 23: ...chtlinie über Elektro und Elektronik Altgeräte über die örtlichen Sammelstellen für Elektronik Altgeräte zu entsorgen Konformitätshinweis Das CE Zeichen ist ein Freiverkehrszeichen das sich ausschließlich an die Behörden wendet und keine Zusicherung von Eigenschaften beinhaltet Bei technischen Fragen zum Gerät wenden Sie sich bitte an Ihren Fachhändler ...

Page 24: ...r chemical means without the written consent of the publisher Typographical and printing errors cannot be excluded However the information contained in this manual is reviewed on a regular basis and any necessary corrections will be implemented in the next edition We accept no liability for technical or typographical errors or the consequences thereof All trademarks and industrial property rights ...

Page 25: ... 29 5 2 Installation 31 5 2 1 Flush mounting box installation 31 5 2 2 Surface mounting box installation 32 5 3 Teaching in 34 6 Operation 36 7 Troubleshooting 36 7 1 Command not confirmed 36 7 2 Duty cycle 37 7 3 Error codes and flashing sequences 38 8 Restore factory settings 39 9 Maintenance and cleaning 40 10 General information about radio operation 41 11 Technical specifications 42 ...

Page 26: ...lease hand over this manual as well Symbols used Attention This indicates a hazard Please note This section contains important ad ditional information 2 Hazard information Do not open the device It does not contain any parts that can be maintained by the user There is a risk of electric shock if the device is opened If you have any doubts have the device checked by an expert For safety and licensi...

Page 27: ...th ods of heat radiation cold and mechanical loads The device is not a toy do not allow children to play with it Do not leave packaging material lying around Plastic films bags pieces of polystyrene etc can be dangerous in the hands of a child We do not assume any liability for damage to property or personal injury caused by improper use or the failure to observe the hazard information In such cas...

Page 28: ...ork is being carried out To avoid electric shocks from the device please disconnect the mains voltage trip the miniature circuit breaker Noncompliance with the installation instructions can cause fire or introduce other hazards When connecting to the device terminals take the permissible cables and cable cross sections into account Loads connected to the relay outputs require sufficient insulation...

Page 29: ...energy limiting class 3 Installation regulations according to VDE 0100 and HD382 or 60364 have to be considered Users must be able to easily access the cable protection switch This must be marked as disconnecting device for the actuator Before the actuator is connected remove the fuse from the fuse box The device may only be operated within residen tial buildings Using the device for any purpose o...

Page 30: ...coverings are moved up and down automatically Shutters and awnings are operated easily via an external push button via remote control or the Homematic IP app Device overview see fig 1 A System button reset button und LED B Fixing lug C Connecting terminal 2 motor up D Connecting terminal 1 motor down E Connecting terminal for L phase conductor F Connecting terminal for N neutral conductor G Connec...

Page 31: ...nnection with various partner solutions The available functions provided by the system in combination with other components are described in the Homematic IP User Guide All current technical documents and updates are provided at www eQ 3 de 5 Start up 5 1 Installation instructions Please read this entire section before starting to install the device Before installation please note the device num b...

Page 32: ...llowing specialist knowledge is particularly important during installation The 5 safety rules to be used Disconnect from mains Safeguard from switching on again Check that system is deenergised Earth and short circuit Cover or cordon off neighbouring live parts Select suitable tool measuring equipment and if neces sary personal safety equipment Evaluation of measuring results Selection of electric...

Page 33: ...24 during in stallation Permitted cable cross sections for connecting to the shutter actuator are rigid cable mm2 flexible cable with without ferrule mm2 0 75 1 50 0 75 1 50 5 2 Installation You can install the shutter actuator in a flush mounting box or in a surface mounting box 5 2 1 Flush mounting box installation To install the shutter actuator in a flush mounting box please proceed as follows...

Page 34: ...p Connect the neutral conductor of the motor to the neutral conductor of the house installation Connect the phase connection of the shutter push button with the phase conductor of the house installation Fix the actuator to an appropriate flush mounting box If required you can remove the fixing lug B Close the flush mounting box using an appropri ate cover Switch the fuse of the power circuit on ag...

Page 35: ...g 2 Connecting terminal S1 G Down Connecting terminal S2 H Up Connect the neutral conductor of the motor to the neutral conductor of the house installation Connect the phase connection of the shutter push button with the phase conductor of the house installation Fix the actuator to an appropriate surface mount ing box e g Abox 025 or Abox 040 see fig 3 Fix the actuator to the holding mandrel using...

Page 36: ...int or to the Homematic Central Control Unit CCU2 For detailed information please refer to the Homematic IP User Guide available for down load in the download area of www eQ 3 de To integrate the shutter actuator into your system and enable it to communicate with other Homematic IP devices you must teach in the device to your Homematic IP Access Point first To teach in the shutter actuator please ...

Page 37: ... device number SGTIN in your app or scan the QR code Therefore please see the sticker sup plied or attached to the device Please wait until teach in is completed If teaching in was successful the LED lights up green The device is now ready for use If the LED lights up red please try again Complete the setup of your shutter actuator by following the instructions in the app In the app give the devic...

Page 38: ...tion until the push button is released or the end position of the shutter or awning is reached 7 Troubleshooting 7 1 Command not confirmed If at least one receiver does not confirm a command the device LED lights up red at the end of the failed trans mission process The failed transmission may be caused by radio interference see 9 General information about radio operation on page 41 This may be ca...

Page 39: ... reach the 1 limit until this time restriction comes to an end Homematic IP devices are designed and produced with 100 conformity to this regulation During normal operation the duty cycle is not usually reached However repeated and radio intensive teach in processes mean that it may be reached in isolated in stances during start up or initial installation of a system If the duty cycle is exceeded ...

Page 40: ... You can continue operation Short orange flashing every 10 seconds Teach in mode active Please enter the last four numbers of the device serial number to confirm see 5 3 Teaching in on page 34 1x long red lighting Transmission failed or duty cycle limit is reached Please try again see sec 7 1 Command not confirmed on page 36 or 7 2 Duty cycle on page 37 6x long red flashing Device defec tive Pleas...

Page 41: ...ttings of the shutter actuator please proceed as follows Press and hold down the system button A for at least 4 seconds using a VDE screwdriver until the LED quickly starts flashing orange Release the system button again Press and hold down the system button again for 4 seconds until the LED lights up green Release the system button to finish the proce dure The device will perform a restart After ...

Page 42: ...ip the miniature cir cuit breaker Only qualified electricians to VDE 0100 are permitted to carry out work on the 230 V mains Clean the device using a soft lint free cloth that is clean and dry You may dampen the cloth a lit tle with lukewarm water in order to remove more stubborn marks Make sure that no moisture will ingress into the housing Do not use any deter gents containing solvents as they c...

Page 43: ...ion within buildings can differ greatly from that available in the open air Besides the transmitting power and the reception characteristics of the receiver environmental factors such as humidity in the vicinity have an important role to play as do on site structural screening conditions Hereby eQ 3 AG Maiburger Str 29 26789 Leer Germany declares that the radio equipment type Homematic IP HmIP FRO...

Page 44: ...ss section rigid and flexible cable 0 75 1 5 mm Installation only in switch boxes device boxes in accordance with DIN 49073 1 or junction boxes surface mounting boxes in accordance with DIN 60670 1 Degree of protection IP20 Protection class II Ambient temperature 10 to 55 C Dimensions W x H x D 54 x 33 x 41 mm Weight 40 g Radio frequency band 868 0 868 6 MHz 869 4 868 65 MHz Maximum radiated power...

Page 45: ...must be dis posed of at local collection points for waste elec tronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive Information about conformity The CE sign is a free trading sign addressed ex clusively to the authorities and does not include any warranty of any properties For technical support please contact your retailer ...

Page 46: ...44 Technical specifications ...