background image

Name and Functions of Buttons:

Functions

If button is held down

SET

- -

Enter clock & calendar
setting

+

1 step forward Alarm,

Fast advance

Snooze Alarm on/ off 

DOWN -/

1 step backward

Fast backward

ZONE

Select PST, MST,

Atomic time seek

CST, EST

CLEAR/

Clear memory at Max/ Min

Alarm time setting

ALARM

display Read alarm time 5
sec at normal mode

MAX/MIN

Read maximum/ minimum
record 5 sec

ALERT

Temp alert on/ off

Enter temp alert setting

CHANNEL

Select Channel 1,2,3,

Delete current channel

auto scroll

SNOOZE/

Backlight on 5 seconds,

LIGHT

Trigger snooze alarm,
stop alarm

1 0

1 1

Remote Sensor/
Channel Indicator

Indoor
Temperature
Reading

LCD Clock

Snooze Button/
Backlight

Temperature
Trend Indicator

Outdoor
Temperature
Reading

Indoor Humidity
Reading

REMOTE SENSOR

HOME RECEIVER

Summary of Contents for EnviraStation DWS-200

Page 1: ...as garantías implícitas incluyendo entre otras aquellas garantías implícitas de idoneidad y comerciabilidad están limitadas a la duración total de dos años a partir de la fecha de compra original Para obtener un servicio cubierto por la garantía para su producto HoMedics puede entregar la unidad personalmente o enviarla por correo junto con su recibo de compra fechado como prueba de la compra el f...

Page 2: ...unit can monitor up to 3 separate sensors Once a channel is registered it will not accept any new sensors However registered channels can be erased by removing the batteries in the remote sensor or the home unit When replacing batteries for the remote sensor Remember to clear the corresponding channel of the home unit by removing the batteries OR Select the respective channel of the sensor by pres...

Page 3: ...ter the 1st channel of the RF thermometer is registered 1 At normal mode hold the button located on the back of the home receiver for 3 seconds to force synchronization 2 The antenna icon will appear during the synchronization process 3 If the icon disappears afterwards radio time signal is not available at that moment Try setting the home receiver in other locations Remember to place the unit awa...

Page 4: ...enter the desired lower limit with buttons press ALERT to confirm and exit 4 You may enter an alert setting for the indoor temp indoor humidity and temperature of the remote sensor 5 When temperature hits the limit of your preset levels the Upper Lower pointers and the temperature of the respective channel indoor or remote sensor will flash and an audible alarm Press any button on the home receive...

Page 5: ...e 2 of the instructions for detailed instructions With the two units next to each other attempt synchronization Remember to always place the remote sensor within the effective transmission range and away from large metal surfaces What is the recommended battery type Your units will come with 4 AA alkaline batteries 2 AA batteries required for each unit We recommend using only alkaline batteries fo...

Page 6: ...ALARM display Read alarm time 5 sec at normal mode MAX MIN Read maximum minimum record 5 sec ALERT Temp alert on off Enter temp alert setting CHANNEL Select Channel 1 2 3 Delete current channel auto scroll SNOOZE Backlight on 5 seconds LIGHT Trigger snooze alarm stop alarm 10 11 Remote Sensor Channel Indicator Indoor Temperature Reading LCD Clock Snooze Button Backlight Temperature Trend Indicator...

Page 7: ...warranties including but not limited to those implied warranties of fitness and merchantability are limited in the total duration of two years from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated sales receipt as proof of purchase postpaid along with check or money order in the amount of 5 00 payable to HoMedics to ...

Page 8: ...modo en caso de usar sensores adicionales Esta unidad puede monitorear hasta 3 sensores diferentes Una vez que se registra un canal no aceptará ningún sensor nuevo Sin embargo los canales registrados pueden borrarse retirando las pilas del sensor exterior o de la unidad interior Cuando cambie las pilas del sensor exterior recuerde borrar el canal correspon diente de la unidad interior retirando ta...

Page 9: ...enga presionado durante 3 segundos el botón que se encuentra en la parte posterior del receptor interior para provocar la sincronización 2 El ícono de la antena aparecerá durante el proceso de sincronización 3 Si posteriormente el ícono desaparece se debe a que la señal horaria de radio no está disponible en ese momento Intente colocar el receptor interior en otras ubica ciones Recuerde colocar la...

Page 10: ... a configurar el límite inferior 3 El puntero inferior y el valor destellarán ingrese el límite inferior deseado con los botones y presione ALERT alerta para confirmar y salga 4 Puede ingresar una configuración de alerta para la temperatura interior para la humedad interior y para la temperatura del sensor exterior 5 Cuando la temperatura llega a l límite de sus niveles preseleccionados los punter...

Page 11: ...ALÁMBRICO que comienza en la página 2 de las instrucciones para obtener más detalles Con las dos unidades cerca una de otra intente la sincronización Recuerde colocar siempre el sensor exterior dentro del ámbito de transmisión efectivo y lejos de superficies metálicas grandes Cuál es el tipo de pila recomendado Sus unidades viene con 4 pilas alcalinas AA se requieren 2 pilas AA para cada unidad 20...

Page 12: ... 5 segundos en el modo normal MAX MIN Lee los registros máximo y mínimo durante 5 segundos ALERT alerta Encendido y apagado de la Ingresa la configuración de alerta de temperatura la alerta de temperatura CHANNEL Selecciona los canales 1 2 3 Borra el canal actual canal avance y retroceso automáticos SNOOZE Iluminación de fondo en de repetición 5 segundos Dispara la alarma LIGHT luz de repetición d...

Reviews: