background image

ROTATION button on the back of the unit. 

2.  To focus, rotate the focus knob to desired result. 
3.  The angle of the projector can be adjusted by angling 

the projection arm forward or backward.

LOW BATTERY INDICATION

Low battery indication is available for the home receiver 
and the remote sensor. A battery life “       ” icon will be
shown on the home receiver or remote sensor. Replace the
batteries as necessary and follow the setup procedure as
mentioned earlier in the “GETTING STARTED” section.

MOUNTING INSTRUCTIONS

Table Top

-

For the home receiver, snap the base into the back of the
unit. For the remote sensor, simply pull out the integrated
stand from the bottom.

Wall Mount

-

For the remote sensor - Set a screw into the desired 
hanging location and mount.

MAINTENANCE AND CARE
INSTRUCTIONS

• Extreme temperatures, shock or areas of unusual vibration

should be avoided to prevent damage to the units.

• Clean the units using only a soft, damp cloth to wipe.  

Do not use solvents, abrasives, detergents or other strong
cleaning agents.  After cleaning, wipe surfaces with a dry
cloth.

• Do not submerge units in water or other liquids.
• Do not subject the units to extremely severe temperatures

- DO NOT PLACE UNITS INTO OVENS, FREEZERS or 

MICROWAVE OVEN.

6

NOTES

•  Opening the housing of either the remote sensor or the home receiver will

invalidate your warranty.  Do not attempt to repair this unit. There are no 
consumer serviceable parts.

•  If you encounter any difficulties in setting up your wireless thermometer 

system, please contact Consumer Relations.

• Your new RF Thermometer is built with random security code technology.

The home receiver will learn the random code of the remote sensors and
log it in as channel 1, then set the additional remote sensors as channel 2
and channel 3 if necessary.  The home receiver can monitor up to 3
separate sensors.

• Once a channel is registered, it will not accept any new sensors. However,

registered channels can be erased by removing the batteries in the
remote sensor or the home unit. 

• When replacing batteries for the remote sensor - Remember to clear the

corresponding channel of the home receiver by removing the batteries,
and unplugging the adaptor or select the respective channel of the sensor
by pressing the CHANNEL button on the home receiver.  Hold the
CHANNEL button for 3 seconds to clear the registration.

• When replacing batteries for the home receiver - Please remove the 

batteries of all remote sensors.  Once you have replaced the home
receiver batteries, re-install the batteries to the sensors and re-log them in
again.  This will ensure that the home receiver and the remote sensors are
properly synchronized.

• Press the Tx button on the back of remote sensor to verify the RF reception.
• It is recommended to test the home receiver and the remote sensor next

to each other to ensure that both are properly synchronized.

•  Keep the remote sensor out of direct sunlight and rain.  Do not mount 

on a metal surface.

About the Atomic Clock

The National Institute of Standard and Technology (NIST) in Fort Collins,
Colorado broadcasts the time signal (WWVB at 60kHz AM radio signal) 
with an accuracy of 1 second per every 3,000 years.  The signal will cover 
a distance up to 2,000 miles from the source.  Like a typical AM radio, 
your Atomic Clock will not able to receive the WWVB signal in places 
surrounded by heavy concrete or metal panels.  The reception of the time

7

DWS-170-IB SP\ENG  10/12/04  11:32 AM  Page 7

Summary of Contents for EnviraStation DWS-170

Page 1: ...ntre otras aquellas garantías implícitas de idoneidad y comerciabilidad están limitadas a la duración total de dos años a partir de la fecha de compra original Para obtener un servicio cubierto por la garantía para su producto HoMedics puede entregar la unidad personalmente o enviarla por correo junto con su recibo de compra fechado como prueba de la compra el franqueo pagado junto con un cheque o...

Page 2: ...ace the unit away from sources of interference such as mobile phones appliances TV etc 4 Antenna icon will appear on screen if the radio time reception is successful The radio controlled clock will have a daily synchronization at 1 00 am everyday If previous attempts of reception were unsuccessful the home receiver will attempt synchronization each hour until successful 5 Each reception cycle is m...

Page 3: ... of projection 1 To turn the projected information 180 degrees press the SETTING ALARM TIME 1 Hold the CLEAR button for 3 seconds 2 To select either first alarm A1 or second alarm A2 Press on back to toggle between selections Press CLEAR to confirm your selecton 3 Set alarm time Press on the back of the unit to enter the desired Hr Min values Press CLEAR to confirm 4 To view alarm time Press CLEAR...

Page 4: ...ver will learn the random code of the remote sensors and log it in as channel 1 then set the additional remote sensors as channel 2 and channel 3 if necessary The home receiver can monitor up to 3 separate sensors Once a channel is registered it will not accept any new sensors However registered channels can be erased by removing the batteries in the remote sensor or the home unit When replacing b...

Page 5: ...olumes of soaking rain may To guard against this we recommend that you mount it under the eve of your house your garage or any other suitable place that will keep it out of direct sun and rain 8 Outdoor Temperature Reading shows This is usually an indication that the channel selector located in the top left corner of the home receiver is set incorrectly to receive the signal from the remote sensor...

Page 6: ... step backward Fast backward Select PST MST Atomic time seek CST EST CLEAR Clear memory at Min Max Alarm time setting ALARM display Read alarm time 5 sec at normal mode MIN MAX Read minimum maximum record 5 sec ALERT Temp alert on off Enter temp alert setting CHANNEL Select Channel 1 2 3 Delete current channel auto scroll SNOOZE Backlight on 5 seconds BACKLIGHT Trigger snooze alarm stop alarm 10 1...

Page 7: ...d to those implied warranties of fitness and merchantability are limited in the total duration of two years from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated sales receipt as proof of purchase postpaid along with check or money order in the amount of 5 00 payable to HoMedics to cover handling Upon receipt we will...

Page 8: ...erencia tales como teléfonos celulares artefactos televisores etc 4 El icono de la antena aparecerá en la pantalla si la recepción de la señal horaria de radio es exitosa El reloj controlado por radio tendrá una sincronización diaria todos los días a la 01 00 am Si los intentos de recepción anteriores fracasaron el receptor doméstico intentará sincronizar cada hora hasta tener éxito 5 Cada ciclo d...

Page 9: ...ará lecturas de Temperatura en descenso si es más de un grado en una hora ALERTA DE TEMPERATURA HUMEDAD Oprima ALERT para encender o apagar la alerta de temperatura y humedad 1 Oprima y mantenga el botón ALERT al respaldo del receptor doméstico por 3 segundos para ingresar al modo de ajuste de alerta El icono de las condiciones al interior empieza a destellar 2 Oprima para seleccionar entre alerta...

Page 10: ...sensores diferentes Una vez que se registra un canal no aceptará ningún sensor nuevo Sin embargo los canales registrados pueden borrarse retirando las pilas del sensor exterior o de la unidad interior Cuando cambie las pilas del sensor exterior recuerde borrar el canal correspondiente del receptor interior retirando las pilas y desenchufando el adaptador o seleccione el canal respectivo del sensor...

Page 11: ...mperatura exterior indica Esto en general indica que el selector del canal ubicado en el rincón superior izquierdo del receptor doméstico no se encuentra ajustado correctamente para recibir la señal del sensor remoto Si usted tiene sólo un sensor remoto asegúrese de que el selector del canal esté ajustado en 1 Para cambiar el canal presione el botón channel canal ubicado en el frente del receptor ...

Page 12: ...T MST Búsqueda de señal CST EST Atómica CLEAR Borra el máx min Configuración de hora ALARM de la memoria que se muestra de alarma Lee el tiempo de alarma durante 5 segundos en el modo normal MIN MAX Lee los registros máximo y mínimo durante 5 segundos ALERT alerta Encendido y apagado Ingresa la configuración de de la alerta de temperatura la alerta de temperatura CHANNEL Selección de Canal 1 2 3 B...

Reviews: