manualshive.com logo in svg
background image

Quick Setup Manual - WS-2815U-IT Professional Weather Station 

The operations manual is posted at the indicated link located at the top of each product page accessed from: 

http://www.lacrossetechnology.com/2815

 Next read the release notes to select the correct free PC software at: 

http://www.lacrossetechnology.com/support/software.php

 (user help is in the software).  

 

Carefully open the package and check that the following contents are complete: 

Wind Sensor 

Rain Sensor 

Thermo-Hygro Sensor

 

Wireless Display 

USB Transceiver 

 
 
 
 
 

 

Mast holder 

 

Right angle adaptor  

 

1 x U-bolts 

 

 

2 W 2 Nuts

 

 

Plastic Reset Rod

 

 

 

 

Base sensor, 
funnel top cover 
and battery cover 
(pre-assembled) 

 

 

 

Airflow cover 

 

Wall mount adapter 

 

Mounting screws 

 

Plastic anchors for screws 

 

 

 

Foldout stand 

 

 

 

 

USB wireless 
interface for 
PC 

 

Wind Sensor also 

Protected under U.S. 

Patent: 6,761,065 

All items, including Wind Sensor, are Protected under U.S. Patents: 

5,978,738; 6,076,044; & 6,597,990 

 

Setup: 

IMPORTANT:

 Make sure to observe the correct polarity when inserting batteries.  The "+" markings on the batteries must line 

up with the diagrams inside the battery compartments.  

Inserting the batteries incorrectly may result in permanent 

damage to the units.

 During the setup process, place the wireless display and the outdoor sensors on a surface with 5-10 

feet between each sensor and the display. 

Only

 

use Alkaline Batteries, rechargeable batteries may not work. Note: Do 

not mix old and new batteries. Do not mix alkaline, standard, or rechargeable batteries. 
 

1. 

It is important to allow sufficient light to reach the solar panel while activating the wind 
sensor. Make sure the lights are on in the setup room and the solar panel is facing a 60W 
light bulb or brighter.  Ensure the panel is not covered, then remove the black protective foil 
on the solar panel.  Remove the tape covering the reset hole.  Use the provided plastic 
reset rod to gently press the reset button once in the hole on the bottom of the sensor. 

2. 

Insert two "AA" size batteries into the rain sensor with the correct polarity. 

3. 

Insert two "C" size batteries into the thermo-hygro sensor with the correct polarity. Allow all 
sensors to run for two minutes.

 

4. 

Insert three "C" size batteries into the wireless display with the correct polarity. 

 

NOTE:

 Every time the wireless display receives data from the sensors, the wireless icons 

 will blink once and then return to solid if the last transmission was successful. A wind 

speed or rainfall amount that reads "0" does not mean reception failure. It means that there was no wind or rain at the 
time of the last measurement. The thermo-hygro sensor syncs with the wind and rain sensors and sends all outdoor 
sensor data to the display. The thermo-hygro sensor tries for 4 minutes to sync to the wind sensor and then 4 minutes 
for the rain sensor.  If not successful within 4 minutes, the thermo-hygro sensor will stop looking for the other sensors. 

5.  Setup troubleshooting:

  

If the sensor data fails to display for any of the outdoor sensors within 10 minutes, (“- - -“ is 

displayed), remove the batteries from all units for 1 minute and start the Setup procedure again at Step 1. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Mounting the sensors and placement of the wireless display: 

 

IMPORTANT:

 

 

Ensure that all of the sensor data can be received at the intended mounting locations before you drill mounting 

holes. The outdoor sensors have a wireless range of 

200-feet

. Keep in mind that the 

200-foot 

range equates to an open-air 

scenario with no obstructions.  Each obstruction (roof, walls, floors, ceilings, etc.) will reduce the range.   

Outdoor Temperature 

Outdoor Humidity 

Rainfall Amount 

Indoor 
Temperature 

Indoor Humidity 

Wind Direction 

Wind Speed 

Forecast Icon and 

Weather Tendency 

Arrows 

Wind Chill 

Time and Date 

Pressure History Graph 

Barometric 

Pressure 

Press Reset Button on 

Bottom of Wind Sensor 

(Solar Panel Must Face 

Light) 

Product Registration: 

lacrossetechnology.com/support/register 

Отзывы: