background image

9

8

Removing Mineral Buildup

One common problem with steamers is mineral buildup caused by the high

mineral content in many municipal water supplies. Mineral residue inside of the

internal pipes and heater can cause intermittent steaming or in severe cases no

steaming at all.

The best way to avoid this is to use de-mineralized or distilled water in the unit.

The procedure below can be used to clear mineral buildup. If you are unable to

use de-mineralized or distilled water we recommend you use this procedure

monthly to help avoid mineral buildup. 

1.

Turn the unit off and unplug the power cord.

2.

Unscrew and remove the hose from the hose connector on the top of the unit.

3.  

Remove the pole from the unit.

4.  

Remove the water tank from the main unit and drain any water in the unit.

5.  

Make a mixture of 50% vinegar and 50% water

. In most cases 1 cup of this 

mixture will be sufficient.

6.  

Slowly pour the water

-vinegar mixture into the hose connector

.

a. If the internal piping is only partially blocked by mineral buildup, the

water

-vinegar mixture will soon start flowing out of the water intake 

hole. If this happens proceed to step 8.

b. If the internal piping is completely blocked, continue to pour the 

mixture into the hose connector till full.

7.  

P

our the water

-vinegar mixture into the water intake hole until full.

8.

Let stand for 40 minutes.

9.

Drain the water using the drain plug.

10. P

our clean water through the hose base and water intake hole until the 

vinegar smell dissipates.

11. 

Reassemble the unit and operate normally

.

If the procedure above does not return the unit to normal operation, the unit may

need servicing.

Trouble Shooting the Steamer

PROBLEM

CA

USE

SOL

UTION

Steamer fails to heat

Steamer not plugged in

Plug in to electrical outlet

Auto shut off engaged

Check water container to 

insure it is not empty

. If full, hit

reset ON/OFF switch on side 

of unit. If empty

, refill and 

push reset to begin.

No steam

W

ater level is low

Turn ON/OFF switch OFF and 

refill water container

W

ater drips from nozzle

Condensation in hose

Hold the hose vertically and 

allow water to drain back into 

tank

Nozzle gurgles

Condensation in hose

Hold the hose vertically and 

allow water to drain back into 

tank

Steam is intermittent

Sediment build-up in 

F

ollow the procedure for 

container

removing mineral build-up

NOTE: 1. W

ater mineral content and conditions will vary in different 

areas. T

o

 insure continued operation of the steamer

, never 

store without cleaning and removing excess water from the 

resevoir and water container

.

2.

If the reset light comes on with water in the tank you 

probably need to declarify (clean) the unit.

3.

In areas where the voltage exceeds 120V

, it may be 

necessary to clean your unit more frequently

.

Hose Connector

W

ater Intake Hole

PS-200C  1/27/05  10:32 AM  Page 9

Summary of Contents for PerfectSteam IBPS200-C

Page 1: ...dañados a causa de estas modificaciones HoMedics no será responsable de ningún tipo de daños incidentales consecuentes o especiales Todas las garantías implícitas incluyendo entre otras aquellas garantías implícitas de idoneidad y comerciabilidad están limitadas a la duración total de dos años a partir de la fecha original de compra Para obtener un servicio cubierto por la garantía para su product...

Page 2: ...Do not leave appliance unattended while connected Burns could occur from touching hot metal parts hot water or steam Use care when you turn a steam appliance upside down there may be hot water in the reservoir Never drop or insert any object into any opening or hose Do not use outdoors or operate where aerosol spray products are being used or where oxygen is being administered Surfaces of this app...

Page 3: ...Safe for use on all types of fabrics Quick heat up feature emits steam in 45 seconds Convenient integrated garment hanger Telescoping design for compact storage 5 flexible hose with Safe Touch hose cover for safe and comfortable handling Easy fill water tank provides 40 minutes of continuous steam Rolling casters for excellent mobility Low water auto shut off for safe use Convenient drain at base ...

Page 4: ...osition Remove and refill water tank by following step 1 under Instructions for Use Push the reset button on side of unit Turn On Off switch to On position 5 When you are finished with your steaming session place the On Off switch in the Off position and remove the plug from the outlet NOTE Be cautious when handling until steamer has fully cooled Cleaning and Maintenance 1 Allow the steamer to coo...

Page 5: ...ter intake hole until full 8 Let stand for 40 minutes 9 Drain the water using the drain plug 10 Pour clean water through the hose base and water intake hole until the vinegar smell dissipates 11 Reassemble the unit and operate normally If the procedure above does not return the unit to normal operation the unit may need servicing Trouble Shooting the Steamer PROBLEM CAUSE SOLUTION Steamer fails to...

Page 6: ... responsible for any type of incidental consequential or special damages All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited in the total duration of two years from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated sales receipt as proof of purchase p...

Page 7: ...tálicas calientes agua caliente o vapor puede ocasionar quemaduras Ponga cuidado cuando voltea boca abajo un artefacto que produce vapor puede haber agua caliente en el recipiente NUNCA lo deje caer ni inserte ningún objeto en ninguna abertura o manguera NO lo haga funcionar al aire libre o donde se utilizan productos de rociado por aerosol o donde se está administrando oxígeno Las superficies de ...

Page 8: ...uridad con cualquier tipo de tejido La función de calentamiento rápido permite producir vapor en 45 segundos Gancho para colgar ropa convenientemente incorporado Diseño telescópico para almacenamiento compacto Manguera flexible de 5 1 5 m con cubierta de manguera Safe Touch para un manejo cómodo y sin peligro El tanque de agua fácil de llenar permite la producción de vapor por 40 minutos seguidos ...

Page 9: ...ire y vuelva a llenar el tanque de agua siguiendo el paso 1 a continuación Instrucciones de uso Oprima el botón de reajuste en el lado de la unidad Gire el interruptor On Off en la posición On encendido 5 Cuando ha terminado su sesión de vaporización gire el interruptor On Off en la posición Off apagado y desconecte el enchufe del tomacorriente ATENCIÓN Maneje el vaporizador con cautela hasta que ...

Page 10: ... 40 minutos 9 Drene el agua usando el tapón de drenaje 10 Vierta agua limpia en la base de la manguera y en el orificio de entrada de agua hasta eliminar el olor a vinagre 11 Vuelva a montar la unidad y úsela normalmente Si el procedimiento de arriba no logra que la unidad vuelva a funcionar normalmente es posible que necesite mantenimiento Solución de problemas del vaporizador PROBLEMA CAUSA SOLU...

Reviews: