37
settings should be reviewed
with your dealer
E. Resin fouling may be
reducing capacity of your resin.
Discuss with your dealer.
8. Excessive salt consumption.
A. Incorrect setting.
B. Excess water in brine tank
A. Confirm settings with your
dealer.
B. See below.
9. Excess water in brine tank.
A. Drain line flow control
plugged
B. Plugged injector
C. Incorrect setting
D. Brine flow problem
A. Inspect and clean the DLFC,
and ensure no blockages in
drain piping.
B. Inspect and clean injector
and injector screen
C. Confirm settings with your
dealer.
D. Inspect brine tubbing for
kinks or blockages, check brine
tube connections for air leak, &
check brine line flow control for
blockage.
9. Softener regenerated at
unexpected time of day.
A. Power failure
A. Reprogram correct time into
controller.
WARRANTY INFORMATION
SoftPlus™ systems are backed by a comprehensive warranty program.
The Fleck 5810XTR2 control valve and related bypass assembly and media tank are
manufactured by Pentair LLC and are subject to Pentair LLC’s Limited Warranty. See
Pentair’s Limited Warranty for details.
Fleck 5810XTR2 control valve: 5 Years*
Media tanks up to 13” in Diameter: 10 Years
Media tanks 14” and Greater in Diameter: 5 Years
*Note: Pistons and piston seals are considered wear and tear items and require regularly
scheduled maintenance and replacement.