6
Installation
(as a fixed luminaire)
1
Preparing the unit for installation
Carefully unpack and lay all parts on a clean, level surface.
Remove the preassembled mounting back plate by unscrewing
the canopy screws (D).
Cut off the power cord and leave minimum 6.5 inches for
electrical connections and slide the wire through the bottom
hole toward back of canopy, then carefully split the cord into
two separate wire leads, ensuring there is no damage to the
cord insulation and trim each wire 1/2 inch back to bare metal
conductor.
4
Installing the fixture
Place the fixture assembly (A) over the mounting bracket (EE)
and align the holes of mounting bracket (EE) with holes on the
fixture assembly (A) and secure with canopy screws (D).
Thread the cap (E) to the bottom hole on the fixture assembly.
Place the shade (C) over the fixture assembly (A) and insert the
shade frame into the two ears of the fixture assembly (A).
Install two 60 Watt E12 Type B Bulbs or CFL or LED equivalent
(not included).
Restore power at source. Turn light on at wall switch and lamp switch.
2
Installing the mounting bracket
Attach mounting bracket (EE) to the junction box (not included)
with junction box screws (FF).
NOTE: The ears of the mounting bracket (EE) should be in a
horizontal position.
EE
EE
A
D
FF
3
Making the electrical connections
Make the connections to a 120V AC 60Hz circuit.
NOTE:
Connect the cord with the ribbed surface to the white wire of the
supply circuit.
Connect the half with the markings and smooth surface to the
black wire of the supply circuit.
Wrap the bare copper grounding wire from the fixture around the
green screw on the mounting bracket (EE), then connect it to the
grounding conductor of the supply circuit.
Use U.L./CSA Listed wire connectors (GG) suitable for the size,
type and number of conductors. No loose strands or loose
connections should be present. Secure the wire connectors (GG)
with U.L./CSA Listed electrical tape.
GG
6.5in./16.51cm
A
C
EE
A
D
E