Holtkamp Electronics DUO 8600XL techn. stand 05.2016 4033_05.2016 V01.2021
- 21 -
12.2.4
Bus configuration menu
This menu is only of interest to you, if you owned a network (HE
-
LIOTEX or DELTA XL) or you need a connection to SkinControl.
If you want to set up a network, please read the instructions,
which are included with the particular software.
to call with:
Therefore the DIP switch no. 3 must set on “on”.
to quit with:
OK
hold OK
button
+
insert chip card
type 53
unhand OK
button
+
pull out chip
card type 53
OK
Following menu options are successively programmable:
Display ad
Factory setting
Description
Device address
1
With the device address you have the possibility, to allocate to the DUO an
address between 1–36 in a bus system. Be careful, that two devices do not
receive the same address.
Every XL device must have a different device no. There may not be distributed
double because the bus system can´t read the particular address. Besides,
the no of the SkinControl device must correspond with the no. of the particular
tanning beds.
Card verify
no
This setting must generally be on "
no
” If “
yes
” is adjusted = “
no contact to the
central
”
Test mode
no
On setting the “
Testing
” you have the possibility, with the setting "
no
", not to
show several error codes. The standard setting is "
no
".
Baudrate
9600
On setting the “
Baudrate
” you have the possibility, to set various data transfer
speed. As smaller the number, so much slower the conduction. You have the
possibility, to choose between 1200, 2400, 4800, 9600, 19200, and 38400. The
standard setting is 9600 baud.
Parität
even
On setting the “
Parity
” you have the possibility, to check the sent data for mis
-
takes. On setting “
even
”, the even number bits will be checked, with the setting
“
uneven
”, the uneven numbers. It will be no checking carried out, with the set
-
ting "
none
". The standard setting is "
even
".