background image

Doorphone Adjustments and Programming 

Page 6

TYPE 115

In certain noisy locations (traffic or wind), the microphone volume may need to be decreased. A symptom
of  this is one-way talk path, in which the distant party cannot be heard over the speaker. A “

MIC VOL

adjustment is provided on the doorphone for increasing or decreasing the microphone volume.

Microphone Volume

The “

SPKR VOL

” pot can be adjusted to increase or decrease the speaker volume to the desired level.

Speaker Volume

The “

maximum number of rings can be adjusted using the DIP switches.

Maximum Number of Rings

Sw 1    Sw 2    Max Rings

OFF     OFF          2

ON      OFF          3

OFF      ON           10

ON       ON           30

1

Disconnect the PHONE LINE INPUT.

2

Slide the TALK BATTERY switch to the ON position.

3

Move DIP SWITCH 2 from OFF to ON.

4

Connect a phone to terminals 4 & 5 -  LINE OUT TO PHONES.

5

Pick up the phone (you will hear a double beep - indicating that you have accessed the PROGRAMMING MODE).

6

You can now Touch Tone program the features listed below

Access Programming Mode (Local Access)

Step

Action

1

Make sure C-1000B is in Programmin Mode - See above

2

Program Strike 1 activation time as follows:

3

Enter time (seconds) followed by #01

4

Program Strike 2 activation time as follows:

5

Enter time (seconds) followed by #02
EXAMPLE:  05#01 programs  Strike 1 for 5 seoncds

03#02 programs  Strike 2 for 3 seconds

Program Gate Strike Relays

Step

Action

NOTE: Entering a time “00” sets time = 1/2 second Maximum time through programming = 9 seconds 

Summary of Contents for 101-VIK

Page 1: ...eedback Access Control Essex stand alone 5 button keypad 1 relay 5 6 users 16 5 VAC power supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 69...

Page 2: ...IKE 1 DOOR STRIKE 2 BATT ON 1 2 3 C O M N O N C 1 KSU 13 8 VAC 1 25A DO NOT CONNECT CO LINE IN 13 5 VAC IN Holovision Face Plates shown with W 1000 installed Talk Battery is ON When used w o CO line K...

Page 3: ...OOR STRIKE 1 DOOR STRIKE 2 TALK OFF BATT ON 1 2 3 C O M N O N C 1 13 8 VAC 1 25A CO LINE IN 13 5 VAC IN Holovision Face Plates shown with W 1000 installed Talk Battery is OFF When used with standard p...

Page 4: ...Plate shown with W 1000 installed Talk Battery is ON When used w o CO line ON OFF Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Remote Bypass Button Gate Strike wit...

Page 5: ...OOR BOX 2 DOOR STRIKE 1 DOOR STRIKE 2 TALK OFF 1 2 3 C O M N O N C 1 13 8 VAC 1 25A CO LINE IN 13 5 VAC IN Holovision Face Plate shown with W 1000 installed Talk Battery is OFF When used with standard...

Page 6: ...ON 30 1 Disconnect the PHONE LINE INPUT 2 Slide the TALK BATTERY switch to the ON position 3 Move DIP SWITCH 2 from OFF to ON 4 Connect a phone to terminals 4 5 LINE OUT TO PHONES 5 Pick up the phone...

Page 7: ...Modes ADDITIONAL C 1000B MODES Doorbell Mode phones will not ring when doorbell is pushed This is useful when conventional door chimes are desired In order to use this feature the Auxiliary Contacts m...

Page 8: ...call waiting tone will be heard To place the call in progress on hold and speak to the visitor push When you want to return to the original phone call push ACTIVATING A DOORSTRIKE OR OPENING A GATE To...

Page 9: ...1 2 Latch 3 4 5 Latch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5...

Page 10: ...seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm new Master Code Set Master Code Step Action 1 Enter Master Code 2 Enter 111 3 beeps 3 Enter User Code 1 4 Wait 5 seconds...

Page 11: ...eeps Set User Code 5 Step Action 1 Enter Master Code 2 Enter address of code to be deleted 111 113 etc 3 Do not enter any code until you hear 3 reset beeps 4 Wait 5 seconds for 3 reset beeps Delete An...

Page 12: ...below Step Action Note The above 2 steps are actually setting the activation times for user code 1 2 and user code 3 4 5 Using the jumper pin setting as shown in Set Essex Relay Options this will set...