TYPE 115

Viking W-1000 Wiring 

Wiring into Unused CO Port on KSU - with Essex Gate Control System -

AC Out For Strike 

VIKING  

Model C-1000B

1  2 3  4 5  6 7  8 9  10 11  12 13  14 15 16  17 18 19 

EAR

TH GND

PHONE LINE INPUT

LINE OUT

T

O

 PHONES

KEYLESS CONT

ACT

DOOR  BOX 1

DOOR BOX POWER

DOOR  BOX 2

DOOR STRIKE 1

DOOR STRIKE 2

TALK
OFF

BATT
ON

1   2   3

C
O
M

N.
O.

N.
C.

1

KSU

13.8 VAC
1.25A

13

.5

V

A

C

IN

Holovision Face Plate shown

with W-1000 installed

“Talk Battery” is ON

When used w/o CO line

ON

OFF

Essex Model 265

NC 2

NO 2

COM 2

NC 1

NO 1

COM 1

DC

OUT

AC

IN

Remote

Monitor

Earth

Remote Bypass Button

Gate Strike with MOV

MOV is recommended

Ke

y

p

a

d

C

a

b

le

16.5 VAC
40 VA

Rela

y

O

u

t

to

E

s

s

e

x

C

o

n

trol

le

r

DO NOT CONNECT CO

LINE IN

NOTE 1: Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip

“color for color”.

NOTE 2: MOV (metal oxide varistor) is the small red component which is included. Its purpose is to

absorb “inductive kick back” which can be created when power is removed from the strike.

Summary of Contents for 101-VIK

Page 1: ...eedback Access Control Essex stand alone 5 button keypad 1 relay 5 6 users 16 5 VAC power supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 69...

Page 2: ...IKE 1 DOOR STRIKE 2 BATT ON 1 2 3 C O M N O N C 1 KSU 13 8 VAC 1 25A DO NOT CONNECT CO LINE IN 13 5 VAC IN Holovision Face Plates shown with W 1000 installed Talk Battery is ON When used w o CO line K...

Page 3: ...OOR STRIKE 1 DOOR STRIKE 2 TALK OFF BATT ON 1 2 3 C O M N O N C 1 13 8 VAC 1 25A CO LINE IN 13 5 VAC IN Holovision Face Plates shown with W 1000 installed Talk Battery is OFF When used with standard p...

Page 4: ...Plate shown with W 1000 installed Talk Battery is ON When used w o CO line ON OFF Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Remote Bypass Button Gate Strike wit...

Page 5: ...OOR BOX 2 DOOR STRIKE 1 DOOR STRIKE 2 TALK OFF 1 2 3 C O M N O N C 1 13 8 VAC 1 25A CO LINE IN 13 5 VAC IN Holovision Face Plate shown with W 1000 installed Talk Battery is OFF When used with standard...

Page 6: ...ON 30 1 Disconnect the PHONE LINE INPUT 2 Slide the TALK BATTERY switch to the ON position 3 Move DIP SWITCH 2 from OFF to ON 4 Connect a phone to terminals 4 5 LINE OUT TO PHONES 5 Pick up the phone...

Page 7: ...Modes ADDITIONAL C 1000B MODES Doorbell Mode phones will not ring when doorbell is pushed This is useful when conventional door chimes are desired In order to use this feature the Auxiliary Contacts m...

Page 8: ...call waiting tone will be heard To place the call in progress on hold and speak to the visitor push When you want to return to the original phone call push ACTIVATING A DOORSTRIKE OR OPENING A GATE To...

Page 9: ...1 2 Latch 3 4 5 Latch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5...

Page 10: ...seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm new Master Code Set Master Code Step Action 1 Enter Master Code 2 Enter 111 3 beeps 3 Enter User Code 1 4 Wait 5 seconds...

Page 11: ...eeps Set User Code 5 Step Action 1 Enter Master Code 2 Enter address of code to be deleted 111 113 etc 3 Do not enter any code until you hear 3 reset beeps 4 Wait 5 seconds for 3 reset beeps Delete An...

Page 12: ...below Step Action Note The above 2 steps are actually setting the activation times for user code 1 2 and user code 3 4 5 Using the jumper pin setting as shown in Set Essex Relay Options this will set...