HOKUYO AUTOMATIC CO.,LTD.
Input and each area
Photo-coupler input(Anode common, Each input ON current 4mA)
Setting detecting area changeover
Set area No. by [Input 1], [Input 2], [Input 3] and [Input 4]
Stop emission by getting all [Input 1], [Input 2], [Input 3] and [Input 4] to ON
(OFF : H level input, ON : L level input)
[Input 1]
[Input 2]
[Input 3]
[Input 4]
[Input 5]
Area patterns
ON ON ON ON ON
Emission stop
OFF ON ON ON ON Area 1
ON OFF ON ON ON Area 2
OFF OFF ON ON ON Area 3
ON ON OFF ON ON Area 4
OFF ON OFF ON ON Area 5
ON OFF OFF ON ON Area 6
OFF OFF OFF ON ON Area 7
ON ON ON OFF ON Area 8
OFF ON ON OFF ON Area 9
ON OFF ON OFF ON Area 10
OFF OFF ON OFF ON Area 11
ON ON OFF OFF ON Area 12
OFF ON OFF OFF ON Area 13
ON OFF OFF OFF ON Area 14
OFF OFF OFF OFF ON Area 15
ON ON ON ON OFF Area 16
OFF ON ON ON OFF Area 17
ON OFF ON ON OFF Area 18
OFF OFF ON ON OFF Area 19
ON ON OFF ON OFF Area 20
OFF ON OFF ON OFF Area 21
ON OFF OFF ON OFF Area 22
OFF OFF OFF ON OFF Area 23
ON ON ON OFF OFF Area 24
OFF ON ON OFF OFF Area 25
ON OFF ON OFF OFF Area 26
OFF OFF ON OFF OFF Area 27
ON ON OFF OFF OFF Area 28
OFF ON OFF OFF OFF Area 29
ON OFF OFF OFF OFF Area 30
OFF OFF OFF OFF OFF Area 31
Input response time
Input taking-in cycle : 1 scanning time(100ms or 110ms)
(When selecting emission stop by external input, input taking-in cycle is 1msec)
Title
Measuring Distance Type Obstacle Detection
Sensor UBG-05LN Instruction Manual
Drawing
No.
C-41-2384 9/17