2. Specifications(Continued)
Starting time
Within 10 sec after turning on the power source(it may take more time in some
case)
Lamps
Power lamp(Green) : Flickers when staring-up or troubled
Output 1 lamp(Orange) : Lights up when detected in area
Output 2 lamp(Orange) : Lights up when detected in area
Output 3 lamp(Orange) : Lights up when detected in area
Connection method
Lead wire 1m long
Ambient illuminance
Halogen/mercury lamp : 10,000lux or less
Fluorescent lamp : 6,000lux(Max. illuminance)
Note) It may malfunction when receiving strong light such as sun light etc.
Ambient temperature/
humidity
-10 to +50
℃
, 85%RH or less(Not condensing and icing)
Vibration resistance
10
~
55Hz, double amplitude 1.5mm Each 2 hour in X, Y and Z directions
55
~
200Hz, 98m/s sweep 2 min. Each 1hour in X, Y and Z directions
Impact resistance
196m/s
2
(10G) Each 10 time in X, Y and Z directions
Protective structure
IP64
Weight
185g/265g including cable
Life
5 years during normal temperature(motor life)
External dimension
60
×
60
×
75mm
Material
Front case : Polycarbonate, rear case : ABS
Setting of detecting area
Setting of output 1 : It is free to set from 0 to 5m for optical axis direction with 7
points pointer.
Setting of output 2 : Linear setting to progressive direction
Fan-shaped setting to optical axis direction
Percentage(%) setting against output 1 pointer
Setting of output 3 : Same as output 2
*1 Accuracy value is depending on our inspection before shipment.
About detecting characteristics
If the reflectance is extremely bad(mourning dress or oil-stained working clothes etc.), it is impossible to measure
even if detection distance is within 1m. Also, it can't detect the retro-reflector stably.
Title
Measuring Distance Type Obstacle Detection
Sensor UBG-05LN Instruction Manual
Drawing
No.
C-41-2384 8/17