HOKUYO AUTOMATIC CO.,LTD.
(3)Detecting area changeover
Max. 15 kinds of area changeover that was set by PC beforehand can be made by outer bit input.
(4)Trouble output
This device provides self-diagnosis function such as LED emission or motor revolution trouble and this output
executes when such trouble.
2.Structure(Light scanning image)
DANGER
* This product is auxiliary safety device and isn't complete safety device. When device is used for application
that may occur serious accident, make sure to prepare other safety device such as bumper sensor etc. Also,
take necessary measures such as backup circuit etc.
Title
Measuring Distance Type Obstacle Detection
Sensor UBG-05LN Instruction Manual
Drawing
No.
C-41-2384 5/17
UBG
Power/input/
output
AGV’s
control
device
At 500 steps:-
Scanning angle 180
°
Step angle 0.36
°
Max. 10m