CONFIGURATION COMMANDS
Configuration Commands Reference
2.10
•
19.01.2007
89
4.4.11 General Commands
4.4.11.1 All data: GALL
Syntax
Command
GALL
Response
list of selected parameters
Description
Get a list of all parameters.
Return value(s)
For an explanation of the response string see the
respective Get commands of the individual
parameters.
Example
Host:
GALL
Module:
Modultype
: 86012
Flashtype
: M29W800DB
Software
: #26157 Aug 06 2004
Version
: 2.22
Frequency
: 65
Bandgap
: 7
Modulation
: 32
EMC
: 322
DectNo
: 735312
SerNo :
10642194
Baudrate
: 115200
Com
: 8,N,1,RTSCTS
CallControl
: 0
Antenna
: 1
Termination
: FT
Equipment
: DCE (var)
CLDPS
: ON
Protocol
: OFF
CTR6
: OFF
Location
: OFF
Multipoint :
OFF
Park: P36000241263412*#
ARI : P36000241263412*#,35808,0
OK
Application
PT, FT
Notes
•
Format may be changed in future versions.
•
Because of possible changes in future, it is not advisable to
implement this command directly in own software. All returned
parameters are based on commands given in the manual.