background image

   EN   

.

   

8

   

L

OW BATTERIES

 

The  two  supplied  batteries  will  last  for  approximately  1  year 
under a normal usage. When the batteries are low, the relative 
icon    will  appear  on  the  display.  It  is  better  to  change  the 
batteries  on  time  in  order  avoid  any  lack  of  heating  supply 
during the day. 
Follow the correct positioning of the batteries according to the 
internal transmitter battery box indications. 
Every time the batteries are removed the transmitter loses only 
the  time.  The  programmed  times,   the  set  temperatures  and 
the transmitter coupling code are maintained memorized. 
 

E

RRORS

 

  In the case of missing communication between the receiver 

and  the  transmitter,  the  red  or  green  led  on  the  receiver 
starts to blink irregularly, after 350 sec of the communication 
being lost. 

  The above error can happen either when the battery power 

on the transmitter is low (battery icon ON on the transmitter 
display)  and  when  the  location  of  the  transmitter  is  not 
suitable (too far a distance or internal home disturbs like a  
concrete wall or electronic interference etc.). 

  Once  the  communication  has  returned,  the  transmitter 

automatically returns to a normal working mode. 

  In  the  case  of  missing  communication,  the  receiver  will 

automatically  switch  on  the  heating  requested  to  the  boiler 
(the  boiler  switching  on  will  depend  on  the  summer/winter 
position  on  the  boiler  dashboard,  not  from  the  thermostat 
request).  This  will  prevent  freezing  in  case  of  missing 
communication between the receiver and the transmitter in 
winter position. 

  If  the  receiver  is  located  at  the  limit  of  wireless  maximum 

distance,  the  receiver  can  lose  the  communication  for  a 
while and then back to normal working mode. 

  In the case of missing supply to the receiver (electrical black 

out), the communication will be lost but at the return of the 

electricity,  the  receiver  will  automatically  return  to  a 
standard working mode according to the transmitter signal. 
There  is  no  requirement  for  any  special  operation  on  the 
receiver/transmitter  in  the  case  of  missing  communication 
unless it is necessary to change location of the transmitter. 

  This  product  has  one-direction  radio  frequency  from  the 

transmitter to the receiver, this means that only the receiver 
can recognize the missing communication. No advise will be 
displayed  on  the  transmitter  in  the  case  of  missing 
communication. 

 
 
 

T

ECHNICAL MENU AND SPECIAL FUNCTIONS

 

(

ONLY FOR EXPERTISE

The weekly thermostat incorporates a technical parameterized 
menu  accessible  only  with  a  password  and  the  use  of  this  is 
recommended for expert personnel only. 
The  parameter  settings  change  the  working  mode  of  the 
thermostat,  therefore  the  modifications  are  allowed  only  if 
required by the particular installation. 
The technical menu is accessible by the main menu under the 
PL  icon  (see  encoder  paragraph  for  the  access  procedure). 
The password to be selected is the number 53. 
Inside the PL menu are present 6 parameters that can be 
adjusted as described below:  

 

Summary of Contents for HRT-177RS

Page 1: ...RELESS manual issue 02 2013 rev 03 HRT 177RS WIRELESS RF WEEKLY ROOM THERMOSTAT Installation and user instruction page 2 EN CRONOTERMOSTATO SETTIMANALE SENZA FILI Manuale di installazione e uso pag 11 IT ...

Page 2: ...al actions required by the installer wiring connections of the receiver to the boiler setting the time and setting the day All the rest like coupling between receiver and transmitter heating pattern default temperatures etc are already pre configured at the factory IMPORTANT these instructions should be read in conjunction with the appliance installation instructions It is recommended that this de...

Page 3: ... selection only for expertise Escape from main menu QUICK START GUIDE To be read and used after a proper installation has been made and after the hours and the working mode has been set WORKING MODE This central heating control device provides you both the room thermostat function and the weekly clock function When in AUTO mode the central heating will be ON OFF according to the programmed times a...

Page 4: ...ture selection 03 hysteresis OFF value selection 04 hysteresis ON value selection 05 encoding and coupling with the RF receiver 06 radio frequency value selection EHIt escape from technical menu for technical menu see dedicated paragraph Exit escape from main menu INSTALLATION AND OPERATING INSTRUCTIONS Unlike the conventional thermostat this control separates the function in two units The receive...

Page 5: ...osition whatever the transmitter request was led green irregularly blinking However it is possible manually move the relay position the heat request to the OFF or ON position permanently by pressing the receiver transparent button The selected position is indicated by the red or green light irregularly blinking Once the radio communication has been reactivated the receiver will revert to work acco...

Page 6: ...s required to encode the transmitter and the receiver this operation should be done while the receiver and the transmitter are still very near see the encoding instructions Before fixing the transmitter check that the radio signal is active if there is no communication the receiver will blink red or green irregularly Because the transmitter uses radio waves to communicate with the receiver you sho...

Page 7: ...ation on the receiver Room temperature calibration Automatic boiler switch ON for radio communication errors missing communication between receiver and transmitter OPERATING INSTRUCTIONS At the first installation the thermostat the time and the day of the week needs to be set see encoder paragraph After this a desired thermostat status must be selected see the encoder paragraph When in AUTO mode t...

Page 8: ...mostat request This will prevent freezing in case of missing communication between the receiver and the transmitter in winter position If the receiver is located at the limit of wireless maximum distance the receiver can lose the communication for a while and then back to normal working mode In the case of missing supply to the receiver electrical black out the communication will be lost but at th...

Page 9: ...period 03 HYSTERESIS OFF The value selected with this parameter indicates when the heat request is stopped The factory setting is 0 4 C values range between 0 0 C and 2 0 C Heat requests switch OFF when the room temperature reaches the room target temperature plus the hysteresis OFF value 04 HYSTERESIS ON The value selected with this parameter indicates when the heat request is activated The facto...

Page 10: ...ating 2 x 1 5AAA Alkaline batteries Temperature setting 3 C to 35 C in 0 2 C increments Display temperature 9 9 C to 50 C in 0 2 C increments Install transmitter and receiver in an environment with normal pollution level Radio range 40 m in free space the range can be altered depending on the installation conditions and on the electromagnetic environment The manufacturer reserves the right to chan...