1. Rotate to select the desired temperature and press to enter. 
2. Press once to activate or deactivate the ADVANCE function. 

Use to “advance” the heating to an ON or OFF period 

3. Press for 3 seconds to enter menu. Rotate to scroll through  

the  menu  choosing  between  status  mode,  economy 
temperature  setting,  time  of  day,  day  of  the  week, 
programmed  times  day  by  day,  technical  menu  (PL)  and 
exit. Press again to modify selected item. 

Status  mode:

  rotate  to  change  the  thermostat  mode 

between  AUTO,  PARTY,  and  OFF,  press  to  save.  The 
press from status mode automatically escapes from menu. 

Economy  temperature  ECOt:

  Rotate  to  select  the  desired 

economy temperature and press to enter. This temperature 
is  used  when  programming  time  is  OFF  in  AUTO  status 
mode.

 

Time of the day:

 rotate to change the hours, press to save. 

Move to minutes; rotate to change minutes, press to save. 

Day of the week:

 rotate to change the day, press to save 

Programmed  times  day  1-7:

  rotate  clockwise  to  set  hour 

ON, rotate anticlockwise to select hour OFF. Clockwise and 
anticlockwise rotation move ahead the time. Press to save. 
Rotate clockwise to move to the following day. It is possible 
to program together days 1

5 and days 6-7 with the same 

pattern in a single operation. 

PL:

  rotate  to  select  the  password  value,  press  to  enter 

inside the technical menu. Rotate to select the parameters: 
01  =  calibration  of  the  temperature  sensor,  02  =  frost 
protection temperature selection, 03 = hysteresis OFF value 
selection,  04  =  hysteresis  ON  value  selection,  05  = 
encoding  and  coupling  with  the  RF  receiver,  06  =  radio 
frequency  value  selection,  EHIt  =  escape  from  technical 
menu. (for technical menu see dedicated paragraph). 

Exit

: escape from main menu. 

 

I

NSTALLATION AND OPERATING INSTRUCTIONS

 

Unlike  the  conventional  thermostat,  this  control  separates  the 
function  in  two  units.  The  receiver  serves  for  wiring 
connections and heat on/off control. The transmitter serves as 
the  user  interface  and  for  temperature  sensing/control.  The 
two  units  are  linked  by  radio  frequency  (RF).  The  RF 
communication is only in one direction from the transmitter to 
the  receiver,  therefore  the  transmitter  does  not  receive  any 
feedback  from  the  receiver,  no  alarm  of  missing 
communication is visible on the transmitter display. 

T

HE  TRANSMITTER

  is  a  wall-mounted 

timer-thermostat.  The  transmitter  can  be 
located  wherever  a  conventional  room 
thermostat  would  normally  be  sited.  No 
wiring  is  required,  as  the  transmitter  is 
battery powered. 
 

T

HE  RECEIVER 

is  connected  to  the  boiler, 

and 

can 

replace 

conventional 

mechanical  or  electronic  time  clock.  The 
receiver  arrives  pre-cabled  and  ready  to 
be  fixed,  therefore  it  is  not  necessity  to 
open the receiver casing. The receiver is 
equipped  with  a  transparent  bubble 
button  that  incorporates  the  button 
function,  the  green  led  function  and  the 
red led function. 
Button functions: 
1. Press once: manually switch ON the heating (relay closed), 

press again to switch OFF. 

2. Press  for  5  seconds:  encoding  procedure  start  up.  After 

success  coupling  there  is  an  automatically  exit  from  the 
procedure. 

 
 

Summary of Contents for HRT-177RS

Page 1: ...RELESS manual issue 02 2013 rev 03 HRT 177RS WIRELESS RF WEEKLY ROOM THERMOSTAT Installation and user instruction page 2 EN CRONOTERMOSTATO SETTIMANALE SENZA FILI Manuale di installazione e uso pag 11 IT ...

Page 2: ...al actions required by the installer wiring connections of the receiver to the boiler setting the time and setting the day All the rest like coupling between receiver and transmitter heating pattern default temperatures etc are already pre configured at the factory IMPORTANT these instructions should be read in conjunction with the appliance installation instructions It is recommended that this de...

Page 3: ... selection only for expertise Escape from main menu QUICK START GUIDE To be read and used after a proper installation has been made and after the hours and the working mode has been set WORKING MODE This central heating control device provides you both the room thermostat function and the weekly clock function When in AUTO mode the central heating will be ON OFF according to the programmed times a...

Page 4: ...ture selection 03 hysteresis OFF value selection 04 hysteresis ON value selection 05 encoding and coupling with the RF receiver 06 radio frequency value selection EHIt escape from technical menu for technical menu see dedicated paragraph Exit escape from main menu INSTALLATION AND OPERATING INSTRUCTIONS Unlike the conventional thermostat this control separates the function in two units The receive...

Page 5: ...osition whatever the transmitter request was led green irregularly blinking However it is possible manually move the relay position the heat request to the OFF or ON position permanently by pressing the receiver transparent button The selected position is indicated by the red or green light irregularly blinking Once the radio communication has been reactivated the receiver will revert to work acco...

Page 6: ...s required to encode the transmitter and the receiver this operation should be done while the receiver and the transmitter are still very near see the encoding instructions Before fixing the transmitter check that the radio signal is active if there is no communication the receiver will blink red or green irregularly Because the transmitter uses radio waves to communicate with the receiver you sho...

Page 7: ...ation on the receiver Room temperature calibration Automatic boiler switch ON for radio communication errors missing communication between receiver and transmitter OPERATING INSTRUCTIONS At the first installation the thermostat the time and the day of the week needs to be set see encoder paragraph After this a desired thermostat status must be selected see the encoder paragraph When in AUTO mode t...

Page 8: ...mostat request This will prevent freezing in case of missing communication between the receiver and the transmitter in winter position If the receiver is located at the limit of wireless maximum distance the receiver can lose the communication for a while and then back to normal working mode In the case of missing supply to the receiver electrical black out the communication will be lost but at th...

Page 9: ...period 03 HYSTERESIS OFF The value selected with this parameter indicates when the heat request is stopped The factory setting is 0 4 C values range between 0 0 C and 2 0 C Heat requests switch OFF when the room temperature reaches the room target temperature plus the hysteresis OFF value 04 HYSTERESIS ON The value selected with this parameter indicates when the heat request is activated The facto...

Page 10: ...ating 2 x 1 5AAA Alkaline batteries Temperature setting 3 C to 35 C in 0 2 C increments Display temperature 9 9 C to 50 C in 0 2 C increments Install transmitter and receiver in an environment with normal pollution level Radio range 40 m in free space the range can be altered depending on the installation conditions and on the electromagnetic environment The manufacturer reserves the right to chan...