background image

   EN   

.

   

5

   

Receiver led: colors and functionality 

L

ED

 

F

UNCTIONS

 

R

EASON

 

Led green ON 
constantly 

Relay closed = 
heating request ON 

Signal received 
from the transmitter 
or end user manual 
button pressing 

Led red ON 
constantly 

Relay open = 
heating request 
OFF 

Signal received 
from the transmitter 
or end user manual 
button pressing 

Led green and 
led red 
blinking 
alternatively 

Encoding procedure 
working 

The receiver button 
has been pressed 
more than 5 
seconds in order to 
start the encoding 
procedure. 

Led green 
blinking  
irregularly 

Lost communication 
with the transmitter 
– heating is ON 
(relay closed) 

Low batteries on the 
transmitter or 
transmitter too far 
from the receiver. 

Led red 
blinking  
irregularly 

Lost communication 
with the transmitter 
– heating is OFF 
(relay open) 

Low batteries on 
the transmitter or 
transmitter too far 
from the receiver. 

 

NOTE 

1

 FOR RECEIVER

:

 

when the receiver is manually moved to 

the  ON  or  OFF  relay  position  (heating  request  ON  or  OFF), 
after  few  seconds  the  relay  position  will  move  according  the 
transmitter request. If it is required for a permanent ON or OFF 
position, please use the transmitter functionality. 

N

OTE 

2

 FOR RECEIVER

: in case of missing radio communication 

(see errors paragraph), the receiver relay moves automatically 
to  the  ON  position  whatever  the  transmitter  request  was  (led 
green  irregularly  blinking).  However  it  is  possible  manually 
move  the  relay  position  (the  heat  request)  to  the  OFF  or  ON 
position  permanently  by  pressing  the  receiver  transparent 

button. The selected position is indicated by the red or green 
light  irregularly  blinking.  Once  the  radio  communication  has 
been reactivated the receiver will revert to work according the 
transmitter requests. 
 

P

ACKING LIST

 

 

                      

Q

TY

 

  RF receiver with 4 wire cable fitted   

  RF transmitter 

 

 

  Screws and wall plugs (drill 5 mm)   

  Adhesive magnetic  

 

 

  Double side adhesive   

 

  Instructions 

 

 

  Batteries 1,5 AAA 

 

 

 

BOILER PREPARATION

:

 

Isolate the appliance from the electrical 

supply and remove the appliance casing and PCB cover (refer 
to boiler installation instructions for specific details). 
The  receiver  can  be  provided  with  or  without  a  male  plug 
according  the  product  code  ordered  and  according  the 
availability  of  female  counterpart  on  the  boiler  side.  The 
version  without  male  plug  is  supplied 
with spade terminals. 
 

Receiver with male plug fitted 

Connect  the  male  plug  (4  pins)  of  the 
receiver to the female plug on the boiler 
(pre-wired on specific boiler models) 
 

Receiver with spade terminals 

Connect  the  spade  terminals  from  the 
receiver  to  the  PCB  terminals  (room 
thermostat terminal black & black, main 
supply terminals blue and brown on the 
main  boiler  supply  socket)  -  figure 
below for a sample boiler connections. 
Blue = main supply 230 Vac = neutral N 

Summary of Contents for HRT-177RS

Page 1: ...RELESS manual issue 02 2013 rev 03 HRT 177RS WIRELESS RF WEEKLY ROOM THERMOSTAT Installation and user instruction page 2 EN CRONOTERMOSTATO SETTIMANALE SENZA FILI Manuale di installazione e uso pag 11 IT ...

Page 2: ...al actions required by the installer wiring connections of the receiver to the boiler setting the time and setting the day All the rest like coupling between receiver and transmitter heating pattern default temperatures etc are already pre configured at the factory IMPORTANT these instructions should be read in conjunction with the appliance installation instructions It is recommended that this de...

Page 3: ... selection only for expertise Escape from main menu QUICK START GUIDE To be read and used after a proper installation has been made and after the hours and the working mode has been set WORKING MODE This central heating control device provides you both the room thermostat function and the weekly clock function When in AUTO mode the central heating will be ON OFF according to the programmed times a...

Page 4: ...ture selection 03 hysteresis OFF value selection 04 hysteresis ON value selection 05 encoding and coupling with the RF receiver 06 radio frequency value selection EHIt escape from technical menu for technical menu see dedicated paragraph Exit escape from main menu INSTALLATION AND OPERATING INSTRUCTIONS Unlike the conventional thermostat this control separates the function in two units The receive...

Page 5: ...osition whatever the transmitter request was led green irregularly blinking However it is possible manually move the relay position the heat request to the OFF or ON position permanently by pressing the receiver transparent button The selected position is indicated by the red or green light irregularly blinking Once the radio communication has been reactivated the receiver will revert to work acco...

Page 6: ...s required to encode the transmitter and the receiver this operation should be done while the receiver and the transmitter are still very near see the encoding instructions Before fixing the transmitter check that the radio signal is active if there is no communication the receiver will blink red or green irregularly Because the transmitter uses radio waves to communicate with the receiver you sho...

Page 7: ...ation on the receiver Room temperature calibration Automatic boiler switch ON for radio communication errors missing communication between receiver and transmitter OPERATING INSTRUCTIONS At the first installation the thermostat the time and the day of the week needs to be set see encoder paragraph After this a desired thermostat status must be selected see the encoder paragraph When in AUTO mode t...

Page 8: ...mostat request This will prevent freezing in case of missing communication between the receiver and the transmitter in winter position If the receiver is located at the limit of wireless maximum distance the receiver can lose the communication for a while and then back to normal working mode In the case of missing supply to the receiver electrical black out the communication will be lost but at th...

Page 9: ...period 03 HYSTERESIS OFF The value selected with this parameter indicates when the heat request is stopped The factory setting is 0 4 C values range between 0 0 C and 2 0 C Heat requests switch OFF when the room temperature reaches the room target temperature plus the hysteresis OFF value 04 HYSTERESIS ON The value selected with this parameter indicates when the heat request is activated The facto...

Page 10: ...ating 2 x 1 5AAA Alkaline batteries Temperature setting 3 C to 35 C in 0 2 C increments Display temperature 9 9 C to 50 C in 0 2 C increments Install transmitter and receiver in an environment with normal pollution level Radio range 40 m in free space the range can be altered depending on the installation conditions and on the electromagnetic environment The manufacturer reserves the right to chan...

Reviews: