Measuring:
Roughly position the slide 2 by moving it manually close to the
reference object.
Lock the locking screw 5 of the fine adjustment mechanism.
Use the fine adjustment screw 13 to position the slide until the
lever dial indicator shows “0”.
Read the measured value at the display.
7. Technical Data
Span of measurement
300/600/1000 mm
Graduations
0.01 mm / .0005”
Error limit
0.05 mm (.002”)
Slide beam cross section
30 x 12 mm
Display
LCD, numeral height 11 mm
Max. speed of positioning
1.5 m/s
Measuring system
inductive
Battery Lithium 3V
Type CR 2032, 230 mAh
Operating time
approx. 2 years (2000 operating hours/year)
Temperature range - in operation
+ 10°C . . . + 40°C
Temperature range - in storage
- 10°C . . . + 60°C
Protection class (to IEC 60529)
IP40
Data output
RS 232 proximity