Modbus Communications 40
HP-327
HIT-4U
Register
(Decimal)
Description
Data
Type
Access Notes
7011
Request Current
Total
FP64
R/W
0 – Max limited by
total decimal point
selection:
99999.999,
999999.99,
9999999.9,
99999999.
This register is also
used to clear total by
writing 0 or set total
by writing desired
value.
16-bit registers
available at
address 7052-7055
(FP64) and 7060-
7061 (FP32)
7013
Request
Previous Day
Total
FP64
RO
0 – 99999999
7014
Request
Previous Day
Run Time
Seconds
FP32
RO
0 – 86400
7015
Request
Previous Hour
Total
FP64
RO
0 – 99999999
7016
Request
Previous Hour
Run Time
Seconds
FP32
RO
0 - 3600
7018
Request Hourly
Download
Pointer
FP32
RO
-1 (cleared logs) -
767
7019
Request Daily
Download
Pointer
FP32
RO
-1 (cleared logs) -
383
Flow-Tech, Inc. | In MD 410-666-3200 - In VA 804-752-3450 | www.flowtechonline.com