Modbus Communications 38
HP-327
HIT-4U
Register
(Decimal)
Description
Data
Type
Access Notes
2059
Frequency 13
FP32
R/W
0.001-5000.000
2061
Frequency 14
FP32
R/W
0.001-5000.000
2063
Frequency 15
FP32
R/W
0.001-5000.000
2065
Frequency 16
FP32
R/W
0.001-5000.000
2067
Frequency 17
FP32
R/W
0.001-5000.000
2069
Frequency 18
FP32
R/W
0.001-5000.000
2071
Frequency 19
FP32
R/W
0.001-5000.000
2073
Frequency 20
FP32
R/W
0.001-5000.000
2075
K-Factor 13
FP32
R/W
0.001-9999999
2077
K-Factor 14
FP32
R/W
0.001-9999999
2079
K-Factor 15
FP32
R/W
0.001-9999999
2081
K-Factor 16
FP32
R/W
0.001-9999999
2083
K-Factor 17
FP32
R/W
0.001-9999999
2085
K-Factor 18
FP32
R/W
0.001-9999999
2087
K-Factor 19
FP32
R/W
0.001-9999999
2089
K-Factor 20
FP32
R/W
0.001-9999999
4000
Pulse Function
U16
R/W
0=off, 1=on, 2=test
4001
Pulse Width
(mS)
U16
R/W
4-300mS
4003
Pulse Scale
U16
R/W
0=0.01, 1=0.1, 2=1,
3=10, 4=100
4005
Analog Out
Function
U16
R/W
0=off, 1=rate,
2=4mA, 3=12mA,
4=20mA
4007
Analog Out Low FP32
R/W
0.000-999998
4009
Analog Out
High
FP32
R/W
0.001-999999
4011
Alarm Function
U16
R/W
0=off, 1=rate lo,
2=rate hi 3=rat lohi,
4=total, 5=test
4012
Total Alarm Set
Point
FP64
R/W
0.001-99999999
4013
Rate Alarm Low
Set Point
FP32
R/W
0.001- Max limited
by rate decimal
point selection:
999.999, 9999.99,
99999.9, 99999
Flow-Tech, Inc. | In MD 410-666-3200 - In VA 804-752-3450 | www.flowtechonline.com