2 Safety instructions
Operating manual mzr-11507
8
Technical data subject to change without prior notice!
Last update: August 2016
Warning
Should a malfunction of the pump occur, do not dismantle the pump on your
own but contact one of HNP Mikrosysteme's service staff for professional
assistance.
2.6
Unauthorized pump conversions and spare part manufacture
Conversions or modification to the device are only permitted with prior consent
of the manufacturer. Original spare parts and accessories authorized by the
manufacturer ensure safety. The use of other parts will annul the liability of the
pump manufacturer for any resulting consequences.
2.7
Improper modes of operation
The safety of operation of the delivered device can only be insured by correct
use, as described in chapter 1. The limit values given in this manual must not be
exceeded in any case.
2.8
General safety instructions
Please observe the following safety instructions
!
The pump may operate at high pressures. For this reason please use only the
delivered accessories and ensure that the employed fittings and tubing have
been prescribed and approved for these pressures.
!
In order to decrease the pressure, provide the system with a
pressure control
valve
directing the excess liquid to the storage tank or back to the suction side.
In the case of blockage of the pressure side the operating pressure can
multiply, this can lead to the damage of downstream components.
!
At a standstill, the liquid may flow through the pump in the direction of the
falling pressure. In order to avoid this unwanted movement, please integrate
non-return valves
(see accessories).
!
Protect the
micro annular gear pump and the electric drive against strokes and
shocks.
!
Under normal working conditions the shaft sealing rings integrated in the
pump prevent the liquid from leaking out of the device. The micro annular
gear pumps are "technically leak-proof" however not "hermetically sealed"
which means it may occur that gases or liquids enter to or escape from the
pump.
The allowed operating parameters of the drive should not be exceeded. In
particular an
incorrect polarity setting
of the supply voltage may lead to
damage of the control unit.
Warning
Please insure, that the totality of the liquid supply accessories such as tubes,
hoses, filters etc. are free from dust or dirt particles. Impurities such as metal,
plastic or glass particles may impair or damage the pump leading to its failure.
Warning
Please operate the pump with a filter featuring 10 µm or smaller pores. It will
protect the pump.