OPERATING CHECK

The tank level gauge can be used right after properly installation as instructed and 
specicial operating procedure or order is not required. Operating can be checked 
using a drive checker as below.  

Handling of Drive Checker

The drive checker is used for confirming of 
level indication and operation of the tank level 
gauge at the time of calibration. 
1. If the checker knob is turned clockwise 
   about 90

o

 (1/4 turn), the float is slightly 

   lifted. 

DIRECTION FOR THE INSTALLATION

1. Use the galvanized or stainless steel pipe for outside tank.  
2. Non linearity due to flexure of pipe must be limited within ±5mm.
3. If the medium in the tank is highly corrosive, use the pipe which is lined. 
4. The float should be positioned as far away from the liquid inlet or tank stirrer as 
    possible. This will limit the effects of turbulence and prevent flow directly hitting  
    the float.
5. Take care not to fold or kink the measuring tape. 
6. During the installation, take care not to allow the measuring tape to get out of the 
    sheave elbows or balancer roller and check if it is positioned properly in a groove 
    of them

.

7.  Do not loosen or unfasten the thumb screw. Otherwise, spring motor winds 
     rapidly and it can bring an accident.    

Check Handl

e

Gauge Head

Drive Checker

NOTE

Above information should be fully acquainted by user and the temperature of 
the medium in a vessel should not be exceed max. +150

o

C. And also, ambient 

temperature should not be exceed  -20 ~ +60

o

C.

2. Above handling of drive checker can confirm the operating of each parts through 
    the indicator.  

Summary of Contents for HLT-1112

Page 1: ...by HEAD OFFICE FACTORY R D INSTITUTE 141 Palhakgol Gil Jori Eup Paju Si Gyeonggi Do Korea Tel 82 31 950 9700 Fax 82 31 943 5600 Website www hitrol com INSTRUCTION MANUAL MAGNETIC COUPLING TYPE TANK L...

Page 2: ...llation Process 1 Installation of Measuring Tape on Elbows 2 Installation of Measuring Tape and Spring Motor Inside the Tank 3 Installation of Measuring Tape Weight Side 4 Reference for the Bottom Anc...

Page 3: ...tion and maintenance Option for remote indication control and switch for alarm Large scale dial enables legible indication even at a distant location The float in a tank floats on the surface of the l...

Page 4: ...g Indicator 2 Points Dial Ambient Temperature 20o C 60o C Fluid Temperature Max 150o C Operating Pressure Up to 5kg cm2 Enclosure Weather Proof IP65 Application Liquid Measuring Range 2 5M 5M Specific...

Page 5: ...ALWAYS THE BEST SOLUTION HITROL CO LTD SYSTEM COMPOSITION AND DETAILS OF PARTS HLT 1112 SCREW TYPE...

Page 6: ...ALWAYS THE BEST SOLUTION HITROL CO LTD HLT 1212 FLANGE TYPE...

Page 7: ...Std NPT 1 1 2 PF 1 1 2 and other Flange ANSI JIS and DIN Material 304SS 316LSS and other Connection Pipe User Scope Connection Socket Flange for Guide Pipe Nozzle Flange User Scope Guide Pipe Connect...

Page 8: ...bottom anchor should be prepared by user 2 Installation of elbow and seal pipe in advance is fine However install the seal pipe on nozzle side to the elbow after installation of measuring tape and we...

Page 9: ...unterclockwise to give a tension to the measuring tape The measuring tape without holes not perforated should not be positioned in the gauge head 2 INSTALLATION OF MEASURING TAPE AND SPRING MOTOR INSI...

Page 10: ...omplete the installation of spring motor after fixing by upper locking ring Fix all spring loaded drum 1 and 2 PRECAUTION When the spring motor gets out of the spring loaded drum larger or excessive f...

Page 11: ...ct the folded measuring tape to the weight as above The length of bolt should not be over 10mm because long bolt can cause a malfunction of the gauge 2 Put the weight connected with the measuring tape...

Page 12: ...clockwise about 90o 1 4 turn the float is slightly lifted DIRECTION FOR THE INSTALLATION 1 Use the galvanized or stainless steel pipe for outside tank 2 Non linearity due to flexure of pipe must be li...

Reviews: