IOM ACHA-ACHBA_201a1201_208000_180901_EN
ACHA / ACHBA
PACKAGED COMPACT
HORIZONTAL AIR - AIR
TECHNICAL SPECIFICATIONS
ACHA / ACHBA
201
251
351
371
401
501
CAPACITIES
Cooling capacity (1)
kW
5,6
7,4
9,7
11,6
12,4
14,1
EER coefficient
2,0
2,2
2,2
2,3
2,4
2,2
Heat capacity (2)
kW
6,1
8,2
9,8
12,0
13,8
16,4
COP coefficient
2,4
2,5
2,6
2,7
2,9
2,8
REFRIGERANT
Type
R-410A
GWP(4)
2088
Load (5)
kg
2,2
2,7
3,8
4,0
4,1
5,0
COMPRESSOR
Type
Rotational
Scroll
Voltage
V
230.1
230.1
230.1 /
400.3+N
400.3+N
Power input (cold) (3)
kW
2,8
3,4
4,3
5,0
5,2
6,5
Current input (cold)
A
9,6
4,6
5,5
7,6
7,9
9,7
Power input (heat) (3)
kW
2,8
3,25
3,8
4,8
5,1
6,4
Current input (heat)
A
8,3
4,4
4,9
6,8
7,1
8,5
INDOOR HEAT EXCHANGER
Type
Coil with aluminum fins and copper tube
Frontal area
m
2
0,20
0,25
0,25
0,31
0,31
0,31
Fin spacing
mm
2,1
2,1
1,8
2,1
2,1
2,1
Pipes diameter
mm
3/8
3/8
3/8
3/8
3/8
3/8
EXTERNAL HEAT EXCHANGER
Type
Coil with aluminum fins and copper tube
Frontal area
m
2
0,22
0,292
0,36
0,4
0,4
0,4
Fin spacing
mm
1,8
1,8
1,8
1,8
1,8
1,8
Pipes diameter
mm
3/8
3/8
3/8
3/8
3/8
3/8
INDOOR FAN
Type
Centrifugal, double aspiration
Model
9/7 DD
9/9 DD
10/10 DD
10/10 DD
10/10 DD
10/10 SS
Motor power
kW
0,120
0,250
0,250
0,373
0,373
0,550
Voltage
V
230-1
230-1
230-1
230-1
230-1
400-3
Nominal current input
A
1,6
1,5
1,9
2,6
2,7
1,6
OUTDOOR FAN
Type
Centrifugal, double aspiration
Model
9/9 DD
10/10 DD
10/10 DD
12/9 DD
12/9 DD
12/9 DD
Motor power
kW
0,37
0,37
0,44
0,55
0,55
1,10
Voltage
V
230-1
230-1
230-1
230-1
230-1
400-3
Nominal current input
A
4,0
4,0
4,3
4,8
4,7
3,0
DIMENSIONS AND WEIGHT
Length
mm
1.175
1.325
1.405
1.455
1.455
1.455
Width
mm
1.109
1.252
1.339
1.389
1.389
1.389
Height
mm
452
504
504
562
562
562
Weight
kg
159
163
214
253
266
266
1.
Calculated according to the standard UNE-EN-14511-2013, for rated water inlet temperature conditions of 12ºC, water outlet of 7ºC and outdoor
air temperature of 35ºC.
2.
Calculated according to the standard UNE-EN-14511-2013, for rated water inlet temperature conditions of 40ºC, water outlet of 45ºC, outdoor
temperature of 7ºC D.B and 6ºC W.B.
3.
Unit power input according to the standard UNE-EN-14511-2013.
4.
GWP: Global Warming Potential (climatic) of 1 kg of greenhouse gas relative to 1 kg of CO
2
, calculated in terms of 100-year warming potential.
5.
Only units with “FLARE” valve as standard (not option) are loaded with refrigerant, the rest of them are loaded with dry nitrogen to prevent the
entry of moisture.