MAINTENANCE
7-51
5
Clean Fuel Solenoid Pump Strainer
--- every 500 hours
Cleaning
When strainer (3) is disassembled, be sure to replace gasket
(2) and (4). Install cover (1) and the magnet only after suffi-
ciently cleaning them. After being assembled, closely check
the air-tightness of strainer (3).
Disassembling/Assembling
To remove cover (1), loosen with a spanner. After cover (1)
is removed, gasket (2), strainer (3), and gasket (4) are easily
removed in order. Wash removed strainer (3) with light oil.
Install strainer (3) in the reverse order of disassembling. At
that time, install gasket (2) into cover (1) first. Then, securely
tighten cover (1) to pump (5) using a spanner.
NOTE: Wrench size: 17 mm
M1GR-07-004
M1U1-07-006
1
2
3
4
5
Magnet
36 mm
28 mm
2.7 mm
1 mm
3
2
4
ø41
ø24
ø51
ø18
ø40
ZX330-3 Class
Fuel Solenoid Pump
M1U1-07-074
Fuel Solenoid
Pump
Fuel Solenoid
Pump
ZX200-3, 270-3 Class
M1U1-07-071
ZX180-3 Class
M1U1-07-098
M1U1-07-103
ZX120-3 Class
Fuel Solenoid Pump
Summary of Contents for ZAXIS 120-3 class
Page 1: ......
Page 3: ......
Page 5: ......
Page 49: ...SAFETY SIGNS Europe Asia Middle and Near East Model Only S 38 MEMO ...
Page 131: ...BREAK IN 2 MEMO ...
Page 191: ...TRANSPORTING 6 MEMO ...
Page 290: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 HYDRAULIC CIRCUIT M1V1 08 001 ...
Page 292: ...8 ELECTRICAL DIAGRAM ...
Page 293: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 MEMO ...
Page 295: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Page 351: ...SPECIFICATIONS 12 42 MEMO ...
Page 455: ...OPTIONAL ATTACHMENTS AND DEVICES 13 104 MEMO ...
Page 461: ...INDEX 14 MEMO ...