OPERATING THE MACHINE
5-17
ZX180-3, 200-3, 270-3, 330-3 Class
Operational procedures for stop valves and selector valve.
Stop Valves
A
Close : When not using attach-
ment or is detached.
Open : When using attachment
A
Stop
Valves
Close
Open
ATTACHMENT
PEDAL
PUMP
ARM
BOOM
MAIN BODY
ATTACHMENT
MULTI MONITOR
MAIN
CONTROLLER
SOLENOID
VALVE
SELECTOR
VALVE
ACCUMULATOR
STOP VALVE
ACCUMULATOR
2nd RELIEF VALVE
STOP VALVE A
2nd RELIEF
STOP VALVE
A
A
M1U1-05-007