OPERATOR'S STATION
1-60
• When the “FH” symbol is displayed on LCD (7), air flow-
in temperature at the vent, air vent (front and rear vents)
locations, fresh air suction port, and blower speed are
maintained at the highest heating conditions. However, in
case the circulation indicator is ON before the “FH” symbol
is displayed, circulation operation is maintained.
Selecting Display Between Celsius And Fahrenheit
1. While depressing both A/C (8) and mode (14) switches,
turn the key switch “ON”.
2. LCD (7) will display “Sd” for approx. 5 seconds.
3. After display “Sd” is deleted, all LED (7) will come ON.
4. After all LED (7) come ON, repeat to press blower switch
(6) four times.
5. Sequentially, press A/C (8) and blower (6) switches at the
same time.
6. Then, the selection mode between celsius and fahrenheit
starts.
Each time fresh air mode switch (13) is pressed, the dis-
play is shifted between celsius and fahrenheit.
When celsius is displayed, LED (7) displays “C.”
When fahrenheit is displayed, LED (7) displays “F.”
Select either one to be preferred.
7. After selection is complete, end by turning the key switch
“OFF”.
LED (7) will display in the selected mode when the ma-
chine is operated next time.
Display on LCD
Celsius (
°
C)
18.0 to 32.0
Fahrenheit (
°
F)
63 to 91
•
Blower Switch (6):
•
When the AUTO indicator is ON, the blower speed is auto-
matically controlled.
•
When the AUTO indicator is OFF, the blower speed is
controlled in 4 steps. When the
button is pressed
with the blower OFF, the blower starts running in the HI
mode. Then, each time the
button is pressed, the
blower speed is reduced by one step. LCD (7) indicates
the blower fan speed. When the
button is pressed
with the blower OFF, the blower starts running in the LO
mode. Then, each time the
button is pressed, the
blower speed is increased by one step. LCD (7) indicates
the corresponding blower fan speed.
M178-01-077
7
Display when the LCD displays “FH” symbol:
M178-01-075
6
AUTO Indicator
6
8
14
13
7
Summary of Contents for ZAXIS 120-3 class
Page 1: ......
Page 3: ......
Page 5: ......
Page 49: ...SAFETY SIGNS Europe Asia Middle and Near East Model Only S 38 MEMO ...
Page 131: ...BREAK IN 2 MEMO ...
Page 191: ...TRANSPORTING 6 MEMO ...
Page 290: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 HYDRAULIC CIRCUIT M1V1 08 001 ...
Page 292: ...8 ELECTRICAL DIAGRAM ...
Page 293: ...HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT 8 MEMO ...
Page 295: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Page 351: ...SPECIFICATIONS 12 42 MEMO ...
Page 455: ...OPTIONAL ATTACHMENTS AND DEVICES 13 104 MEMO ...
Page 461: ...INDEX 14 MEMO ...