Chapter
4:
Maintaining the storage system
Ongoing proper maintenance of the storage system maintains the reliability of the
storage system and its constant availability to all hosts connected to it.
For more complex maintenance activities, contact customer support.
Storing the storage system
If the storage system does not receive power for more than six months, the battery can
become discharged and possibly damaged. To avoid this situation, charge the battery for
more than three hours at least once every six months.
Note: Do not store the equipment in an environment with temperatures of
104ºF (40ºC) or higher because battery life will be shortened.
Powering off the storage system
Use the following procedure to power off the storage system. The main switch on the
controller chassis is used to power off the storage system.
Before you begin
■
Ensure that all software-specific shutdown procedures have been completed. Refer to
the applicable user manuals for details.
■
Ensure that all I/O activity to the storage system has stopped. You can vary paths
offline and shut down the attached hosts.
Procedure
1. Press the main switch on the controller chassis for approximately three seconds
until the
POWER
LED on the front of the chassis changes from solid green to a
blinking status.
2. Release the main switch and the
POWER
LED returns to solid green after blinking for
approximately three seconds.
The power-off process begins. The process takes approximately 18 minutes or
longer depending on the amount of data that needs to be written. The
POWER
LED is
solid green during the powering off process. The
POWER
LED changes from green to
amber when the process is completed.
3. Verify the
POWER
LED on the front of the storage system changes from green to
amber.
Chapter 4: Maintaining the storage system
Hitachi Virtual Storage Platform F350, F370 Hardware Reference Guide
31